Baumer SXC80 Panduan Pengguna - Halaman 38

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kamera Digital Baumer SXC80. Baumer SXC80 48 halaman. Sxc series cameralink cameras with truesense imaging sensors
Juga untuk Baumer SXC80: Panduan Memulai Cepat (2 halaman)

Baumer SXC80 Panduan Pengguna
Figure 41 ►
Channel Link
®
operation.
38
9.

CameraLink

®
The CameraLink
 interface was especially developed for cameras in machine vision ap-
®
plications and provides high transfer rates and low latency. Depending on the configura-
tion (Base, Medium or Full) the transfer rate adds up to 680 MBytes/sec.
Cameras of the Baumer SXC series are equipped with a CameraLink
therewith able to transmit up to 240MBytes/sec.

9.1. Channel Link and LVDS Technology

CameraLink
bases upon the Channel Link
®
is more beneficial for machine vision.
Channel Link
 in turn is an advancement of the LDVS (Low Voltage Differential Signaling) 
®
standard – a low power, high speed interface standard.
The Channel Link
 technology consists of a transmitter receiver pair, whereat 21, 28 or 
®
48 single-ended data signals and a single-ended clock signal can be wired on transmitter
side. Within the transmitter the data is serialized with a ratio of 7:1. Afterwards the four re-
sulting data streams and the clock signal are transferred via five LVDS pairs. On receiver 
side the four LVDS data streams and the LVDS clock are reordered to parallel signals and
afterwards forwarded to further processing.
9.2.

Camera Signals

The standard designates three different signal types, provided via standard CameraLink
cable:
9.2.1.
Serial
Communication
The standard regulates two LVDS pairs are allocated for asynchronous serial communi-
cation between the camera and the frame grabber. Cameras and frame grabbers should
support at least 9600 baud serial communication.
®
 technology, but provides a specification, that 
®
 Base interface and 
®