A helpful rule of thumb is:
The theoretical maximum production rate where output pulses follow each other without any gap in
between is 3 times higher than the recommended value given by the rule of thumb. Exceeding the
recommended value of the production rate increases the risk of missing edges due to irregular intervals
between copies.
The following table lists the recommended maximum production rate for some values of the output pulse
length.
If suddenly the Scatec starts to miss copies while the production rate is run up, the reason very often is
too short an output pulse length for the actual production rate in combination with fluctuations of the
interval between copies.
Manual SCATEC-2
Version 2021-09
Output pulse length p in milliseconds must be shorter than 1.2 million
divided by the production rate given in copies per hour
set
output pulse length
[milliseconds]
1
2
5
10
15
20
www.baumer.com
recommended maximum
production rate
[copies/hour]
1,200,000
600,000
240,000
120,000
80,000
60,000