9.1 Explanations on the operational parameters
Default values are either the underlined input values or the input value in [square brackets].
C0:
Input values:
Function:
Comments:
User manual Scatec-10 / -15
Version 2017-10
Pulse Length
0.3ms – 99.9ms in increments of 0.1ms
to set the duration of an output pulse
On the one hand, the duration of an output pulse must be long enough so that the
customer's control system can process it. On the other hand, the length of the
output pulse limits the maximum counting rate. Because output pulses must not
overlap, the interval between edges must be at least as long as one output pulse
length. If the interval is shorter, then this edge will be suppressed meaning that the
edge will not initiate an output pulse.
The following figure illustrates how every other edge is suppressed because of a too
long of an output pulse length.
Scatec-1x
on
a
off
high
p
low
high
low
time
The maximum acceptable output pulse length for a given production rate can be
read from the diagram below.
40
35
30
25
20
15
10
5
0
0.010
www.baumer.com
a
p
Maximum acceptable output pulse length and
production rate
t
r
0.100
production rate [million copies / h]
14 / 44
[Pulse Length]
[10ms]
amber edge-LED
output pulse
pulse length p < interval a
output pulse
pulse length p > interval a
some edges are suppressed!
t: theoretical
r: recommended
1.000
10.000