1.9 Start-up
Is the device set and programmed correctly (function; for coun-
ters, max. counting frequency)?
1.10 Failure possibilities and causes
Impossible to use the keys:
- Key lock input activated
Counter does not count:
- Wrong or reversed wiring of the counting input
- Setting of an input signal not matching the pulse generator
- Polarity (NPN/PNP) reversed
Overview
Model
Operating mode
ISI30.010AX01
Count
ISI30.012AX01
ISI30.013AX01
ISI31.010AX01
Cnt.Dir/Up.Dn
ISI31.011AX01
ISI31.013AX01
Up.Dn
ISI32.013AX01
Cnt.Dir
ISI33.010AX01
Quad/Quad2
ISI33.011AX01
Table 1
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A:
Counting input
INP B:
Counting direction input
Up.Dn:
Differential counting input
INP A:
Adding counting input
INP B:
Subtracting counting input
Quad:
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Quad2:
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
8
- No ground connection between the pulse generator and the
counter
- Signal levels do not reach the switching threshold of the counter
If, despite all, your device still does not operate, contact your
local representative or call us directly for technical support.
When sending your device back, please attach a short descrip-
tion of the failure, of the programming and of the connection
diagram, in order to allow us to reproduce a possibly existing
defect and to repair your device as quickly as possible.
Counting inputs
INP A
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
PNP
04 ... 30 V DC
Options:
AC input modes:
Count:
Cnt.Dir:
Up.Dn:
www.b umer.com
INP B
7 kHz 00 ... 0,7 V DC
12 kHz
00 ... 0,7 V DC
30 Hz
10 ... 260 V AC/DC
7 kHz
00 ... 0,7 V DC
12 kHz
04 ... 30 V DC
10 ... 260 V AC/DC
30 Hz
10 ... 260 V AC/DC
3 kHz
00 ... 0,7 V DC
6 kHz
04 ... 30 V DC
x = A: no backlight
x = B: with backlight
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input.
NPN
30 Hz
NPN
AC/DC
0–
7 kHz
NPN
PNP
12 kHz
30 Hz
AC/DC
30 Hz
AC/DC
NPN
3 kHz
PNP
6 kHz