Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Penghitung Uang Tunai Baumer ISI31.011AX01. Baumer ISI31.011AX01 20 halaman. Display counter
Main technical features:
Display:
LCD, 8 decades, height of the figures 8 mm.
Display range:
-9999999 ... 99999999
with leading zeros suppression.
Overflow:
In case of a display range overflow, the
counter starts again from 0, but without
removing the leading zeros and activating
all decimal points.
In case of a display range underflow, the
counter starts again from 0 and displays
the minus sign, without removing the lead-
ing zeros and activating all decimal points.
Keys:
Electrical locking of the reset key
Housing:
Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2
+0,3
x 45
Mounting depth:
approximately 48 mm
Weight:
approximately 50 g
Protection level:
IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm
Input specification, pin assignment and adjustable operating modes (DC versions).
A control input (screw terminal 5) allows adjusting the operating mode.
Screw terminal
Nr. 1
Designation
INP A
Model
7 kHz
ISI30.010AX01
ISI30.012AX01
12 kHz
ISI31.010AX01
7 kHz
ISI31.011AX01
12 kHz
ISI33.010AX01
3 kHz
6 kHz
ISI33.011AX01
Table 2
Screw terminals 1 and 2:
Function and max. frequences (Pulse/Pause 1:1)
see Table 2
NPN :
active for negative edge
Input resistance:
approximately 1 MOhm
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
+0,6
mm
2
2 x 0,75 mm
2
AWG 26-14
Nr. 3
Nr. 2
INP B
Reset
NPN
30 Hz
NPN
PNP
NPN
NPN
NPN
7 kHz
PNP
12 kHz
PNP
NPN
3 kHz
NPN
PNP
6 kHz
PNP
www.b umer.com
Connection diameter:
0,4 ... 2,3 mm single-wire
AWG 28-12
EMC:
Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Device safety:
Design to:
EN61010 Part 1
Protection Class:
2
Application area:
Soiling Level 2
Low Voltage Directive (for the AC models):
EN 61010 Part 1 ; overvoltage category 2,
contamination level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately, 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 ... +70°C
Altitude:
to 2000 m
Backlighting:
external electrical source
(24 V DC ±20 %, 50 mA)
Nr. 4
Nr. 5
Reset
Control inputs for operating
Enable
mode (Mode)
contact with
not active
=
subtracting
adding
not active
contact with
=
Cnt.Dr Mode
Up.Dn Mode
not active
contact with
=
Quad Mode
Quad2 Mode
PNP :
active for positive edge
Input resistance:
approximately. 100 kOhm
Low level:
0 .. 0,7 V DC
High level:
4 .. 30 V DC
ISI30, ISI31, ISI32, ISI33
Nr. 6
Nr. 7
Nr. 8
GND
BL
–
GND =
GND =
GND =
BL
+