Dover Almatec Biocor B 20 Series Petunjuk Pengoperasian dan Pemasangan - Halaman 3
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Pompa Air Dover Almatec Biocor B 20 Series. Dover Almatec Biocor B 20 Series 10 halaman.
Technical data
Dimensions (mm): length
Nominal port size (please see page 12)
Air connection
Weight (kg)
Max. particle size of solids (mm)
Suction lift, dry (mWC)
Suction lift, wet (mWC)
Max. driving and operating pressure (bar)
Max. operating temperature (°C)
Theoretical displacement volume
per single stroke (l)
Sound pressure level acc. to DIN 45635, part 24,
depending on the operating data [dB (A)]:
Performance curves
The data refer to water (20°C), without using of a pulsation dampener.
width
height
driving pressure 3 bar
driving pressure 5 bar
driving pressure 7 bar
B 20
B 32
see
see
page
page
12
12
-
-
R 1/4"
R 1/4"
12
26
3
5
2
2.5
9
9
7
7
80
80
0,11
0,31
68-71
69-71
73-75
71-75
74-78
73-76
3