Baumer HUBNER BERLIN Low Harmonics HOGS 75 Petunjuk Pemasangan dan Pengoperasian - Halaman 27

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan dan Pengoperasian untuk Peralatan Industri Baumer HUBNER BERLIN Low Harmonics HOGS 75. Baumer HUBNER BERLIN Low Harmonics HOGS 75 32 halaman. Sine encoder version with support plate for a torque arm
Juga untuk Baumer HUBNER BERLIN Low Harmonics HOGS 75: Petunjuk Pemasangan dan Pengoperasian (24 halaman), Panduan Petunjuk Pemasangan dan Pengoperasian (36 halaman), Panduan Petunjuk Pemasangan dan Pengoperasian (36 halaman)

Baumer HUBNER BERLIN Low Harmonics HOGS 75 Petunjuk Pemasangan dan Pengoperasian
9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
MB175aT1 - 11173568
5 VDC ±10 % (version DN ...)
9...26 VDC (version DN ... R)
≤90 mA
1024...2048 (as ordered)
90°
Zero pulse, width 90°
Optical
K1, K2, K0 + inverted
SinCos 1 Vpp
-50 dB
≤20 mV
200 kHz (-3 dB)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø75 mm
ø17 mm (cone shaft 1:10)
≤170 N axial
≤250 N radial
IP56
≤10000 rpm (mechanical)
≤4 Ncm
180 gcm²
Housing: aluminium die-cast
Shaft: stainless steel
-20...+70 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Connecting cable
860 g
Baumer_HOGS75K-A-T1_II_DE-EN (19A1)
9
Technical data
24