Baumer N 150 Panduan Petunjuk Pengoperasian - Halaman 19

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Peralatan Industri Baumer N 150. Baumer N 150 21 halaman.

5. Error warnings

5.1. CRC error

Upon recognizing a CRC error in a transmitted command the SPA will respond as follows:
SOH
Adr
Response
01h
20h

5.2. Format error

Upon recognizing a format error (incorrect length of protocol or void command (Cmd) in a command transmitted
the SPA will respond as follows:
SOH
Adr
Response
01h
20h

6. Overview on commands

The following chart shows in alphabetical order all available commands (Cmd) as well as options regarding read
and write (parameterization).
Command
Data amount
code
in bytes
a (61h)
5
b (62h)
8
c (63h)
8
i (69h)
1
t (74h)
6
u (75h)
6
A (41h)
2
C (43h)
3
K (4Bh)
-
Q (51h)
1
R (52h)
6
S (53h)
8
U (55h)
6
V (56h)
2
X (58h)
4
Z (5Ah)
6
Error
EOT
CRC
65h
04h
46h
Error = „e" (65h) = CRC error
Error
EOT
CRC
66h
04h
40h
Error = „f" (66h) = Format error
read
write
Broadcast
X
X
-
X
X
-
X
X
-
X
X
X
-
X
-
-
X
-
X
X
X
X
-
-
-
X
X
-
X
X
X
-
-
X
X
-
X
X
-
X
X
X
X
-
-
X
X
X
www.baumer.com
Save in
Significance
EEPROM
X
Read / write general parameter
X
Parameter: tolerance compensation, window
X
Parameter: scaling of spindle pitch
X
Parameter: mm / inch
-
Transmit tool number
-
Transmit optional column of figures
X
Assign or indicate device identifier
-
Check if actual value = target
X
Profile reset
X
Specific command: N 150 reset
-
Read actual value
X
Read / write target
-
Offset
X
Read / write profile number
-
Specicfic command: read version number
X
Set preset
N 150
19