Baumer N 150 Panduan Petunjuk Pengoperasian - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Peralatan Industri Baumer N 150. Baumer N 150 21 halaman.
3.4. Data transmission properties
For reasons of compatibility, within the complete multicon system the data amount is always the same (see table
in chapter 6), no matter how many digits are provided in the display. For example, command "R" (read actual
value) comprises a transmitted data amount of 6 bytes, but only 5 digits are indicated in the
3.5. Broadcast commands
Some specific commands are designated so-called broadcast commands. As soon as the master broadcasts a
command to identifier 99, the command is addressed to every N 150 in the network. Each individual spindle
position display will accomplish the respective command but will not respond any confirmation to master.
3.6. Data saving
Specific parameters are saved in EEPROM (1.000.000 writing cycles). Data saving is via interface upon every
parameter transmission to SPA.
Important:
There should not be a cyclic transmission of these parameters to SPA but only if necessary, for example in case
of parameter alteration. The relevant parameters saved in EEPROM are listed in the charts in chapter
"Command explanations" or "Overview on commands".
4. Command explanations
4.1. General information
The following is describing the individual interface commands broken down into the four groups below:
operating commands
-
parameter commands [ commands for SPA parameterization ]
-
identifier commands
-
specific commands
-
The following abbreviations are applied:
SOH
= Start of heading (header token)
EOT
= End of transmission (footer token)
Adr
= Device identifier /address, including offset 20h
Cmd
= Command
Data
= Data transmitted or received
4.2. Operating commands
Command
Data length
code
in bytes
C (43h)
3 / 11
R (52h)
6
S (53h)
8
U (55h)
6
V (56h)
2
Z (5Ah)
6
t (74h)
6
u (75h)
6
[ commands required during operation ]
[ commands to indicate or alter the device identifier (address)]
[ commands for specific functions as device reset or version number readout]
read
write
Broad-
cast
X
-
X
-
X
X
X
X
X
X
X
X
X
X
-
X
-
X
www.baumer.com
Save in
Significance
EEPROM
-
-
Check if current value = target
-
-
Read current value
-
X
Read/write target
-
-
Offset
X
Read/write profile number
X
Set preset
-
-
Transmit tool number
-
-
Transmit optional column of figures
N 150
display.
6