Amphenol Wind-Lok Series Panduan Petunjuk Instalasi - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Kabel dan konektor Amphenol Wind-Lok Series. Amphenol Wind-Lok Series 12 halaman.

Part 3:
Assembly of Gland with EMI Function
As shown in Figure 6 is the M50 gland with EMI function. During the connector installation, the shielding layer needs
to be cut for the second part of the first step of stripping. The cutting length of the shielding layer is reserved 15mm
to ensure that the shielding layer can contact the reed of the gland, as shown in Figure 7 below.
Figure 6
As shown in Figure 8 is the M63 gland with EMI function. In the connector installation, it is necessary to increase the
shielding layer for the second part of the first step of stripping. The cut length of the shielding layer is about 38mm
between the cable cut and the outside of the gland nut to ensure that the shielding layer can contact the shielding
layer of the gland, as shown in Figure 9 below.
Note: The gland with EMI function used in the 5b terminal type is shown in Figure 8, and the length of L is 30mm.
Figure 8
L= 15mm
Figure 7
Figure 9
L= 38mm
7