Dover PSG Blackmer LGL156A Petunjuk Pemasangan, Pengoperasian, dan Pemeliharaan - Halaman 7

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan, Pengoperasian, dan Pemeliharaan untuk Pompa Air Dover PSG Blackmer LGL156A. Dover PSG Blackmer LGL156A 12 halaman. Liquefied gas pumps

Dover PSG Blackmer LGL156A Petunjuk Pemasangan, Pengoperasian, dan Pemeliharaan
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
Hazardous pressure
emptied
can cause serious
personal injury or
property damage
Maintenance shall be performed by qualified technicians
only, following the appropriate procedures and warnings
as presented in this manual.

MAINTENANCE

NOTICE:

Torque Table 1

Head / Casing Capscrews (21)
Relief Valve Cover Capscrews
Bearing Cap Capcrews (28)

STRAINERS

Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.

LUBRICATION

To avoid possible entanglement in moving parts do not
lubricate pump bearings, hydraulic adapter coupling or
any other parts while pump is running
If pumps are repainted in the field, ensure that the grease
relief fittings (76A) are functioning properly after painting.
Do NOT paint them closed.
from the fittings.
Pump bearings and hydraulic motor couplings (if equipped)
must be lubricated every three months at a minimum. More
frequent lubrication may be required, depending on the
application and the operating conditions.
Recommended Grease:
Mobil® - Mobilgrease XHP222,
Exxon® - Ronnex MP Grease
or equivalent Lithium grease.
Greasing Procedure:
1.
Remove the grease relief fittings (76A) from the bearing
covers (27) or hydraulic motor adapter (135).
2.
SLOWLY apply grease with a hand gun until grease
begins to escape from the grease relief fitting port. Discard
excess grease in accordance with the proper codes and
regulations.
3.
Replace the grease relief fittings (76A).
DO NOT over grease pump bearings. While it is normal for
some grease to escape from the grease tell-tale hole after
lubrication, excessive grease can cause mechanical seal
failure. The tell-tale hole is located in the head (20) between
the bearing (24) and the mechanical seal (153).
501-K00
Page 7/12
Ft-lbs
N-m
Ft-lbs
N-m
Ft-lbs
N-m
NOTICE:
NOTICE:
Remove any excess paint
30
40.7
20
27
20
27