The 3 figures below show the operation clearly.
Carry out a control on 4 points:
At the top - at the bottom - on the left - on the right
It is important to control the alignment at every step of
installation in order to ensure that none of these steps
generates stress on the pump unit or the pump itself :
• after fastening on foundations
• after fastening the piping
• after the pump has operated at normal operating
temperature.
REMINDER :
Do not rely on the flexible coupling to compensate for
misalignment.
2.9 Electric motors
WARNING
DISCONNECT THE ELECTRICITY SUPPLY
BEFORE ANY MAINTENANCE OPERATION.
Dangerous voltage.
Can cause
injury and death .
Check that the supply voltage matches the indications
on the motor rating plate.
Comply with the wiring diagram, make sure the wires are
rated for the power and take care with the contacts
which must be thoroughly tightened.
The motors must be protected by appropriate circuit
breakers and fuses.
Connect the regulatory ground connections.
Check the direction of rotation :
WARNING
OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPERTY
DAMAGE, OR DEATH.
Do not operate
without guard
in place.
NT 1003-D00 09.12 AF HT e
2. INSTALLATION (continued)
Correct
Axial alignment
out of true
Angular alignment
out of true
This fundamental checking of the pump must be done
without any product, with the inlet and outlet circuit open
to the air, for example, to avoid any risk of an unexpec-
ted pressure rise. Start the pump empty to check the cor-
rect operation of the connections and check that the
direction of rotation corresponds to installation's inlet
and outlet direction. Follow the instructions below if
necessary to change the direction of rotation.
Three phase motor : switch any two wires or two phases
of the current supply.
Two phase motor : switch the two wires of the same
phase.
Single phase motor : comply with the instructions of the
manual supplied with the motor.
2.10 Diesel engine drive
CAUTION
Excessive temperature-
can cause injury or
severe damage.
Do not forget that these engines are not reversible. It is
therefore vital to carefully check the inlet and outlet sides
of the pump before connecting the pump unit to the
piping.
The use of diesel engines is now well known.
Nevertheless, we strongly recommend that you carefully
read the technical manuals concerning them.
6/18
THE SURFACES CAN BE AT A TEMPE-
RATURE LIABLE TO CAUSE INJURY
OR SEVERE DAMAGE.