Amphenol RESMLAC 28 MG Panduan Instalasi - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Router Jaringan Amphenol RESMLAC 28 MG. Amphenol RESMLAC 28 MG 15 halaman. Ip67 rugged ethernet managed switch
Juga untuk Amphenol RESMLAC 28 MG: Panduan Instalasi (15 halaman)
Section 3
As with any electronic device, you should place the switch where it will not be subject to
Selecting a
extreme temperatures, humidity, or electromagnetic interference that exceeds the
Site
RESMLAC28MG's profile. Specifically, the site you select should meet the following
requirements:
The switches are pre-equipped with plastic or metallic caps on all ports, including power
and Ethernet.
Make sure all connectors are protected with cap or sealed plug to
ensure sealing and prevent from deterioration of the contacts.
The RESMLAC28MG Ethernet Switch can be fastened to any flat surface by mounting the
Mounting
box directly or installed inside a 19'' rack. Refer to the mechanical drawings below. Make
sure to allow enough room to route your Ethernet and power cables.
Two types of brackets are available:
6x Screws with flat and spring washer are needed to fix the brackets onto the switch.
Screw type: Pan head screw #8-32 UNC - 0.5" stainless steel
RESMLAC 28MG IG rev. 1.1
Amphenol
– 948, Promenade de l'Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com
Installation
The ambient temperature should be between -35 to 75 degrees Celsius.
The relative humidity is recommended to be less than 95% percent, non-
condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for MIL-STD-461E.
Type A for 19'' rack mounting
Type B for mounting on any flat surface. By default type B is proposed.
Brackets type A for rack 19'' mounting
Brackets type B for flat surface mounting
Page 5 of 14
Last Rev: 28-Nov-11