end call and video by pressing call button again, and the VDP will return to standby interface.
2.3 Monitoring Function
Under standby interface, by pressing monitor button, you may view video from door
station on the screen. You may turn off monitoring by pressing monitor button again, and VDP
will return to standby interface.
2.4 Unlocking Function
When call from door station, call door station or VDP monitors door station, you may
remotely unlock door station by pressing unlock button.
2.5 DND Function
Under standby status, you may turn on DND function by long pressing call button for 5s;
meantime the screen turns on, there will be corresponding message at left middle position.
Under DND, when door station calls, you may use the video function without incoming ring.
You can connect and start to talk by pressing call button.
Note: For program of some versions, under DND status, message will directly inform you
that VDP is busy.
The default DND is 8 hours, and after 8 hours, it will be automatically canceled. To
manually turn off DND: under standby status, long press call button for 5s to turn it off.
2.6 Viewing Announcement
When there is no alarm, VDP receives message sent from platform, and the indicator
flashes slowly. By pressing monitor button, you can view announcement which is added i n the
video on door station in rolling display. You can exit announcement viewing by pressing
monitor button again.
Note: When there is alarm, you must confirm the alarm before viewing announcement.
2.7 Alarm Function
2.7.1 Arming/Disarming Function
Under standby status, you may enter arming status by pressing arm button, and then the
screen will be on. Arming message will be displayed at left middle position, while the indicator
is on (when there is no announcement or alarm). Under standby status, long pr ess arm button
for 5s, the device will disarm, and screen will be on. Disarming message will be displayed at
left middle position, while the indicator is off (when there is no announcement or alarm).
2.7.2 Alarm Message and Reporting Function
VDP has 8 channels for alarm, with first channel fixed for manual alarm, second channel
fixed for gas alarm, third channel fixed for smoke alarm. When VDP is under arming, excluding
first channel, for alarm triggered in any other channel, its corresponding alarm message will be
displayed on screen, meanwhile VDP's indicator will flash and ring (first channel excluded).
You may confirm alarm message by pressing monitor button, and then indicator resumes, ring