Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Perabotan Dalam Ruangan Foldcraft Plymold Z000000055. Foldcraft Plymold Z000000055 3 halaman. Bolt down seat and table posts

Dining Counter (Bolt Down)
Assembly
Step 1: Moun ng Posts to Concrete Floor
a.
Mark the center loca on of each post onto the floor. (
b. Drill 5/8" diameter hole, a minimum of 2" deep into the cement at the marked loca ons
c.
Blow out the dust from the holes
d. Place an anchor into each of the 5/8" dia. Holes. (Note: The flange at the top of the an‐
chor should be res ng on the cement surface.)
e. Insert the se ng tool into the anchor and hit it with a hammer un l the shoulder of the
se ng tool contacts the flange of the anchor.
f.
Place the bolt down post over the anchors loca ons.
g.
Use a plas c bag or wrapper over the head of the 1/2"‐13 x 1‐1/4" hex head bolt. Insert it
into the socket of the 'T' wrench provided. (The plas c bag helps keep hex head bolt from
falling out during installa on.)
h. Insert the 'T' wrench with bolt down the hole in the top of the column.
i.
Insert the bolt into the anchor in the floor and turn the 'T' wrench to ghten. (do not fully
ghten at this me.)
j.
Ensure that the pots are orientated square to the counter edge.
k.
If needed shim posts to level by placing metal washers under the base plate.
l.
A er post is oriented and straight ghten bolt firmly.
NOTE: At the installers discre on, one can add addi onal holding power in cases where the
quality of the concrete is poor. You can do this by inser ng masonry screws through the
outer 4 holes of the base plate under the bell cover.
Step 1B: Moun ng Posts to Wood Floor
a.
Mark the center loca on of the 4 outer holes.
b. Drill 3/16" x 1 1/2" deep hole in the wood floor in the marked loca ons.
c.
Place the post back over the 4 pre‐drilled holes.
d. Using a 1//4" x 1‐3/4" Long Lag bolt and a 5/16" washer fasten the posts to the floor
Step : Clean
a.
Clean for use.
Address 615 CENTENIAL DRIVE
KENYON, MN 55946
Web
Plymold.com
Phone 800.PLYMOLD
CEMENT
ANCHOR
BELL COVER RAISED UP TO
ACCESS HOLES FOR WOOD
FLOOR MOUNTING
A Division of Foldcra
Page 3 of 5
SETTING
TOOL
5/8" HOLE
T‐WRENCH
HEX HEAD
BOLT
BOLT DOWN
POST