COMBA BBU NG Panduan Instalasi - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Penguat COMBA BBU NG. COMBA BBU NG 8 halaman.
3
SYSTEM TURN UP PROCEDURE
Confirm the connections and polarities for all AC and DC Connections.
Wake up the Battery:
Momentarily press the RESET button located on top of the LiFEPO4 battery to wake it up approximately 3
seconds. Once the first SOC (State of Charge) LEDs begins to illuminate, release the RESET button immediately
(NOTE: Holding the RESET button longer than approximately 5 seconds will cause the battery to go back into
sleep mode. If this occurs, repeat the step to "wake-up" the battery by momentarily pressing the RESET button)
Turn on the system: (no sequence required)
.1
AC Breakers in the BBU
.2
Battery Breakers on the battery
.3
Turn on AC (POWER) Switch in the BDA
The DC (Boot w/o AC) switch in the BDA is used to turn on the system when there is no AC source so the system
can bootup with Battery. It is recommended to leave it OFF under normal conditions.
System Init. Status
OFF
OFF
ON
ON
ON
ON
ON
ON
The LED indicators help user to check the equipment status.
Identifier
Color
RUN
Green
ALM
Red
DRY1
Red/Green
DRY2~8
Red
Table 4: AC and DC Switches
AC and DC Switches
AC SW Init. Status
OFF
OFF
ON
OFF
ON
ON
ON
OFF
Table 5: LED Status
Indication
Operation indicator, flashes every second to indicate normal operation.
Alarm indicator. ON = Dry Contact Alarms; OFF = No Alarm.
Green/OFF = Normal/No Alarm; Red=Alarm
Alarm indicator. ON = alarm; OFF = No Alarm.
DC SW Init. Status
OFF
OFF
OFF
ON
ON
ON
OFF
ON
Action
System Status
AC SW ON
DC SW ON
ON (Run on Batt.)
DC SW ON
ON (No Change)
AC SW ON
ON (Start Charging)
AC SW OFF
ON (Run on Batt.)
DC SW OFF
ON (No Change)
AC SW OFF
DC SW OFF
ON
Shutdown
Shutdown