Dovre 500cc Panduan Instalasi dan Pengoperasian - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Kompor kayu Dovre 500cc. Dovre 500cc 19 halaman.
-7-
48"
I
(50")
1
t
I
,
r--
36"08")
-I
;0"
t
r
I
I
T
!--12.!!..
8
10"
04")
~
1 "
SIDEWALL CLEARANCES AND
FLOOR PROTECTOR SIZE
BACKWALL CLEARANCES WITH
TOP FLUE CONNECTION
(DENOTES CANADIAN REQUIREME NTS)
=
0
r---24"
~
STANDARD
45° CORNER INSTALLATION
BACKWALL CLEARANCES WITH
REAR FLUE CONNECTION
12"04")
FLOOR
PROJECTION
A COMBUSTIBLE FLOOR MUST BE PROTECTED FROM THE RADIANT HEAT GIVEN OFF BY THE STOVE AND
FROM THE INEVITABLE SPARK OR FALLING EMBER. THIS INCLUDES ALMOST ANY FLOOR SURFACE.
ONLY A SOLID MASONRY OR CONCRETE FLOOR ADEQUATELY COVERING THE DISTANCE AROUND YOUR
UNIT IS ACCEPTABLE. A LAYER OF THIN BRICK OR CERAMIC TILE OVER A COMBUSTIBLE FLOOR IS
INSUFFICIENT.
TO PROTECT YOUR FLOOR, IT IS NECESSARY TO INSTALL A FLOOR PROTECTOR OF ONE LAYER OF 3/8"
NON-COMBUSTIBLE MILLBOARD I-IAVING A THERMAL CONDUCTIVITY OF K
=
0.84 BTU IN/FT2
HR F,
DR AN EQUALLY THICK LISTED FLOOR PROTECTOR. THE REQUIRED DIMENSIONS OF FLOOR PROTECTOR
VARY ACCORDING TO THE LENGTH OF CHIMNEY CONNECTORAS SHOWN. IF YOU CONSTRUCT YOUR OWN
FLOOR PROTECTOR WITH THE ONE LAYER OF MILLBOARD, WE SUGGEST THAT IT THEN BE COVERED
WITH CERAMIC TILE, OR THIN BRICK, AND FRAMED TO PROTECT THE MILLBOARD AND GIVE IT A
FINISHED LOOK.
ANY HORIZONTAL LENGTH OF CHIMNEY CONNECTOR PIPE MUST ALSO HAVE THE FLOOR PROTECTOR
BENEATH IT AND EXTENDING 2" ON EACH SIDE Of THE PIPE. THE REQUIRED FLOOR PROTECTOR SIZE
fOR MODEL 500CC IS 48" X 36". IN CANADA, A fLOOR PROTECTOR OF 50" X 38" IS REQUIRED.