Discharging low-voltage protection
In discharging, the over-discharge protection
will start and battery stops to supply
electricity if the voltage of any single cell is
lower than the protection value. The
protection will be dismissed after the voltage
of all cells returns to the range of rated
hysteresis value.
3.4.2 Current Protection Function
Charging over-current protection
System stops charging if charging current is
over the protection value. Protection is
dismissed after a period of time. Please pay
attention that the maximum charging current
shouldn't exceed to the protection value
when using the battery.
3.4.3 Temperature Protection Function
Charging low/over-temperature protection Discharging
In
charging,
system
temperature protection and stops charging if
the battery temperature is over protection
range,
and
dismisses
temperature returns to rated hysteresis value.
3.4.4 Other Protection Function
Short circuit protection
System starts short circuit protection if it
occurs to short circuit when battery starts
working from a shutdown state.
4. Running Environment
Running Environment
Working temperature
Relative humidity
User Manual of Home Energy Storage System (Split Type)
In charging, the system will stop charging
if the voltage of battery module or any
single cell reaches to the protection value.
The protection will be dismissed after the
battery module voltage and cell voltage
return to the range of rated hysteresis
value.
System stops discharging if discharging
current is over the protection value.
Protection is dismissed after a period of
time. Please pay attention that the current
required by electrical equipment shouldn't
exceed to the protection value when using
the battery.
protection
starts
charging
In discharging, system starts discharging
temperature
supplying
protection
after
temperature is over the protection range,
and dismisses protection after temperature
returns to rated hysteresis value.
Battery will shut down automatically after
it has no external loads and power supply
for 48 hours.
Charging over-voltage protection
Discharging over-current protection
low/over-temperature
protection
electricity
Automatic shutdown
Condition
0℃ - 50 ℃
5% - 95% ,no condensation
and
stops
if
the
battery