Comcater GL9-.G Panduan Petunjuk Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk panggangan Comcater GL9-.G. Comcater GL9-.G 6 halaman. Gas-heated charcoal-grill series 90

INSTALLATION INSTRUCTIONS

CONFORMITY TO REGULATIONS AND LAWS
The appliance is to be installed by an authorised person in
accordance with AS5601 - the installer must ensure the
installation complies with all regulatory and manufacturer
requirements and operationally and functionally test, make
necessary adjustments and commission the appliance as part
of installation.
WARNING
The manufacture declines any responsibility if these
obligations are not respected.
INSTALLATION
The overall dimensions/connections and technical data are
given in the appendix.
If the appliance cannot be adjusted to perform correctly call
the tecnichal assistant service.
Positioning
• Install the appliance in a suitably ventilated environment.
• Position the appliance at least 10 cm from surrounding
walls. This distance may be reduced if the walls are
flameproof or protected by insulating material.
• This appliance is not designed for built-in installation.
• Remove the protective film from the external panels.
Use a suitable solvent to remove any glue residue.
• In stand-alone installations, appliances 40 or 60 cm wide
must be fixed to the floor using the flanged feet.
• Level the appliance by means of the adjustable feet.
Joining appliances togheter in line (Fig. 1)
• Position the appliances next to each other and level to the
same height.
• Fix the appliances together using the holes provided in the
side of the top
Connecting to the gas supply
• Install a shut-off valve upstream of the appliance, in a
place easily accessible.
• Check if the appliance is adjusted for the type of gas with
which it will be supplied. If not, convert it according to the
instructions in the paragraph "Conversion to different type of
gas".
• Check that there are no leaks at the connection points.
CONVERSION TO A DIFFERENT TYPE OF GAS
To convert the appliance to a different gas supply, follow the
instructions below.
Use the injectors contained in the bag supplied with the
appliance.
(3042500/FS) 3/6
Replacement of burner injector and adjustment of
burner air flow (Fig. 4)
• Remove the front panel.
• Unscrew the existing injector "U" and replace it with the
one indicated in Table T1 in Appendix.
• Position the air regulator at the distance "A" indicated in
Table T2 in Appendix.
• Retighten screw V and seal it with red paint.
Adjustment of minimum flow to the burner (Fig. 2)
• Remove the front panel.
• Unscrew the existing screw "VM" and replace it with the
one indicated in Table T1 in Appendix.
Replacement of pilot burner injector (Fig. 3)
• Remove the front panel.
• Unscrew fitting R and replace injector UP with the one
indicated in Table T1 in Appendix.
• Retighten fitting R.
COMMISSIONING PROCEDURE
Testing the gas system
• Switch on the appliance following the instructions for use.
Test burners ignition and flame uniformity. Also check the
appliance for gas leaks and make sure the gas exhaust system
functions correctly.
• If necessary, consult the "Troubleshooting guide" below.
Testing the gas nominal thermal power
• After installation, conversion to a different type of gas or
servicing, check the nominal thermal power of the appliance.