Follett 110FB425A Panduan Instalasi - Halaman 15

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Dispenser Follett 110FB425A. Follett 110FB425A 17 halaman. Ice and water dispenser

Follett 110FB425A Panduan Instalasi
SensorSAFE model troubleshooting guide
Problem
Action
Does not
Check
dispense ice
LEDs on the
and/or water.
SensorSAFE
control board.
Place cup
under drop
zone (in front
of lens).
Dispenses ice
Check LEDs
and/or water
on control
continuously.
board.
SensorSAFE Board LED
Status
ICE/
PWR
CLN
WTR
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
Corrective Action
Check circuit breakers and power switch.
Restore power or replace defective switch.
Press clean switch on lower left side of electrical
enclosure to return board to normal operation.
Troubleshoot appropriate lens/sensor
and replace if required (see lens/sensor
troubleshooting).
Verify power on appropriate output terminal
(WTR or WM) on control board and replace
board if required. If board tests okay,
troubleshoot appropriate dispenser component.
Troubleshoot appropriate lens/sensor
and replace if required (see lens/sensor
troubleshooting).
If there is power on any output terminal (WTR or
WM) on control board, replace board.
110CT425A/W, 110FB425A/W
15