POLIBLITZ ABEK 15 "Ex" – sticker placed on the respirator case.
II 1 GD T6 X
= ATEX marking symbols (*)
(*)
SYMBOL
MEANING
II
Group to which this apparatus belongs. Group II refers to apparatuses NOT to be used in mines.
1
Category of this Certified apparatus (products designed to function in zone 0 and 20).
G
Permissible explosive atmospheres surrounding the apparatuses can be flammable gases, vapors and mists.
D
Permissible explosive atmospheres surrounding the apparatuses can be flammable dusts.
T6
Maximum surface temperature of the apparatus is 85°C.
X
Means that the user must wear antistatic cloths and shoes and use non sparkling tools.
8
STORAGE AND MAINTENANCE
Poliblitz ABEK 15 is protected by a plastic case with a sealing red duct tape so no particular attentions are required for storage. Otherwise it
has to be stored in a range of temperature between 2°c and 50°C and the contact with considerable thermal, vibrational source and strong
hits have to be avoided.
Although the sealing plastic case, Polibritz ABEK 15 is required to be maintained every 4 years. By using the Poliblitz maintenance kit, (code
43390.240), the following instructions should be attended:
-
Open the plastic case;
-
Replace the filter;
-
Put the Poliblitz ABEK 15 inside the plastic case, taking care not to deform the rubber half mask;
-
Close the plastic case;
-
Apply the sealing red duct tape on the case along the closing line;
-
Apply on the metal fastening the new expiry date plate.
After use, Poliblitz ABEK 15 has to be restored in "ready for use" condition by getting the Poliblitz maintenance kit, (code 43390.240) and
attending the instructions above described, except the first one as the device has already been extracted from the plastic case for use.
Important note: the information given in this manual is sufficient for the correct use of the escape self-rescue respirator POLIBLITZ ABEK
15. Any further information on SEKUR filters or on POLIMASK half masks can be found in the relevant manuals freely available on the
manufacturer's web site: www.dpisekur.com.