Comelit 1622 Panduan Teknis - Halaman 17
Jelajahi secara online atau unduh pdf Panduan Teknis untuk Unit Kontrol Comelit 1622. Comelit 1622 20 halaman. Button interface
Juga untuk Comelit 1622: Panduan Teknis (20 halaman), Panduan Teknis (20 halaman), Petunjuk Teknis (14 halaman), Panduan Teknis (8 halaman), Panduan Teknis (6 halaman)

Using the external unit relay on lock-release or actuator control
230 V
+
12V/24V
AC-DC
10A MAX
Local lock release button.
Door open indication use variant
Only for use in systems with a single external unit without switching devices Art. 1224A, Art. 1424.
N.C. contact for DOOR OPEN indication. The LED for the following internal units flashes: Art. 2610 with R.I. 008, Art.
2619 with R.I. 000.
C
G
S
P
D
NC NO
-
O
N
E
R
O
M
D
f "C.NC.NO relay activation on actuator command: 2 sec"
f Set the dip switches permanently as shown in the figure (Dip switch ON 8, Dip switch
OFF 1,2,3,4,5,6,7)
Applies to Art. 1622L.
Applies to Art. 1622 with R.I. 038 or greater
-
+
120-230 V
J1
J1
R
V V
L
L
T
-
+
J2
J2
E
33436
1622
-
+
120-230V
1595
1595
SB/RTNP
SB/DO
17