Dr. Bridge KHG Panduan Pengguna - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Akuarium Dr. Bridge KHG. Dr. Bridge KHG 20 halaman. Auto alkalinity doser

Dr. Bridge KHG Panduan Pengguna
11.
Please note, if the alkalinity obtained by the KHG deviate by 1.5 dKH from your desired dKH setting ("KH
auto correction"), KHG will show error messages. KHG will assume this is a major deviation and will
suspend all subsequent dosing of sodium bicarbonate solution and enter into a forced reboot and return
back to standby mode. If the tested value is larger than the "KH auto correction" by +1.5 dKH, KH>ERR will
appear. If the tested value is less than the "KH auto correction" by -1.5 dKH, KH<ERR will appear.

Main Display

Please make sure the RJ45 network cable is securely attached and connect
KHG to your home router or LAN. After switching on KHG, the display panel
will show the IP and port number automatically assigned by the network DHCP
(Figure 7). Please write down the IP and port number shown on the display,
and enter it to the browser of your computer or mobile device to access controls
of the KHG.
If your network DHCP did not automatically assign an IP to KHG, the default IP
will be 192.168.1.10.
For example, if the display were shown as Figure 7, then you should enter
http://172.22.20.158:8090 into your browser. When the login window appears
as Figure 8, enter the password (default setting is "Admin") and Click Login
button, then you will be able to access the controls of KHG as Figure 9.

Main Control of KHG

1.
Get dKH
Press to test and obtain KH value. Counter will be reset after the
testing is completed.
2.
Purge Chamber
Press to purge and empty all solutions in the reactor chamber.
This must be performed every time you intend to move the
KHG. It is crucial to purge reaction chamber to prevent solutions
damaging the optical lens and other electronic components.
Failure to purge chamber could result in KHG failure.
3.
SW Tube De-Gas
Press to pump saltwater sample into the reaction chamber. This
is normally only used at initial setup of KHG, or after reassembly
of the step motor head. By pressing it, saltwater will pump water
up the feeder tube, purging gas from the tube. If there were
blockage in the feeder tube, after a preset amount of time no
water has been pumped into the reaction chamber, the display
would show S.W_ERR error message.
Page 5
User Manual
(Figure 7)
(Figure 8)