Electrolux 925060324 Prosedur Diagnostik - Halaman 6
Jelajahi secara online atau unduh pdf Prosedur Diagnostik untuk Kulkas Electrolux 925060324. Electrolux 925060324 14 halaman.
Displayed
Function
code
Test
Water Valve
53
Dispense +
Main Valve
Ice Maker
56
Water Valve+
Main Valve
Fresh Food
71
Defrost
Heater
72
Ice Maker
Defrost
Heater
Copyright 2018 ELECTROLUX HOME PRODUCTS PTY LTD Technical Services
Action Available
Press (MODES) to
change the status
of the Function
Press (MODES) to
change the status
of the Function
Press (MODES) to
change the status
of the Function
Press (MODES) to
change the status
of the Function
ARESI1006
Behavior Expected
c. Be prepared to collect water at
dispenser.
d. Water dispenses when "on"; stops
when "oF".
e. Press (MODES) button to change the
status
a. Remove ice tray to collect water
into a measuring container to
measure water fill.
b. If collecting water into ice tray, first
perform test n° 50 to empty ice tray.
c. Water flows in the tray when "on".
The Function is active for the time
correspondent to ice tray water fill
setting. According to water setup
configured it is possible to check very
high pressure, normal pressure, low
pressure, very low pressure; once
that the configured time is elapsed the
Function goes automatically to "oF"
state.
d. Press (MODES) button to change the
status
a. Heater on when "on", off when "oF".
b. Fresh Food Evaporator Defrost
Sensor temperature is flashed on the
display.
c. Watch for temperature increase with
the heater on.
d. It may take a few minutes for the
evaporator to heat up. Maximum 5
minutes ON or 45°C Fresh Food Evap
Defrost sensor threshold.
e. Press (MODES) button to change the
status
a. Heater on when "on", off when "oF".
b. IceMaker Evaporator Defrost Sensor
temperature is flashed on the display.
c. Watch for temperature increase with
the heater on.
d. It may take a few minutes for the
evaporator to heat up. Maximum 5
minutes ON or 45°C IM Evap Defrost
Sensor threshold.
e. Press (MODES) button to change the
status