Dramm Autofog MLVH-10A Panduan Pemilik - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Penyemprot Cat Dramm Autofog MLVH-10A. Dramm Autofog MLVH-10A 20 halaman.

Dramm Autofog MLVH-10A Panduan Pemilik
Spraying Procedure
1. Vacate the treatment area, secure all entry ways
and post hazard signs.
2. Prepare the chemical solution. See page 10 for
dilution rate details. Be sure that the solution is
free of clumps of chemical that may clog the
nozzle. Use a whisk or blender to make a smooth
paste of wettable powder solutions. Check that
the suction tube screen is in place in the tank.
Pour the solution through the large solution
strainer/ funnel assembly to eliminate any unmixed
chemical or debris.
3. Plug in the main power cord. Notice the power
lamp illuminated on the control panel.
4. Set the timer. Turn the dial past, then return to
the desired operation time. The MLVH-10A will
begin to spray, vacate the treatment area
immediately.
5. If horizontal airflow fans are used, allow them to
run a half hour longer than the predetermined
spray time.
6. In order to allow all of the spray particles to settle,
do not re-enter the treatment area for a minimum
of 6 hours after the MLVH-10A has completed its
operation. Keep the structure airtight. However, if
it is necessary to enter the treatment area during
application, only do so in a full spray suit, boots,
gloves, hood and respirator.
7. After spraying, ventilate the treatment area with
fresh air and clean the MLVH-10A thoroughly.
Follow all EPA Guidelines for re-entry.
DISCHARGE TIMES FOR MLVH-10A
Clear Water
1.0 liter
2.0 liters
3.0 liters
4.0 liters
5.0 liters
6.0 liters
7.0 liters
How To Set The Timer
1. Plug the AutoFog into the appropriate power
2. Set the clock to the correct time. The timer is a 24
3. Determine the spray starting time and stopping
4. Flip ALL of the pins between the starting and
5. The AutoFog will run only during the time that the
6. The AutoFog is now ready and will begin fogging at
NOTE:
Time
30 minutes
1 hour
1.5 hours
2.0 hours
2.5 hours
3.0 hours
3.5 hours
Timer Settings
The MLVH-10A should be allowed to run for a half
hour after all chemical has been expelled into the
air. See the chart below for approximate amount
of time it takes to expel chemicals. These times
were compiled with clear water - the expulsion
time time may exceed these guidelines when
mixed with chemicals.
Times may vary due to the consistency of solution
being sprayed. Thicker solutions
may take longer to discharge.
source.
hour timer for accuracy between day and night.
time.
stopping time to the OUTSIDE. (see photo below)
pins are flipped to the outside of the clock. DO
NOT FLIP THE START TIME AND STOP TIME
ONLY. Each pin represents 15 minutes of time.
the appropriate time. Make sure the treatment
area is secure and will be empty of all personnel at
that time.
Remember to add a half hour to the spraying time
when setting the timer.
Dramm Autofog MLVH-10A Manual
A video on programming
your timer is available on
our website.
12