Section 8 - Limit Adjustments

Please Note: Screen limits are factory set. Instructions below for
minor adjustments only. Please check with Draper prior to resetting
screen limits.
Please Note: If Access Fit E/V is "Right Hand Motor" or "Waterfall," the
WHITE/DOWN
(I)
and YELLOW/UP
Section 8.1 - Limit Adjustments
Section 8.1.1 - "Down" Limit Adjustment
To Reduce Screen Drop:
1. Raise screen surface approximately
1'
(30 cm)
above desired setting and
turn off.
2. Turn DOWN
(I)
limit screw clockwise
(3 screw turns =
1
/
roller
revolution).
2
3. Test by lowering screen. Repeat
steps 1 & 2 until desired position is
reached.
Please Note: For Quiet Motor with alternate limit screws, WHITE screw = UP and
RED screw = DOWN. However, limits are reversed if surface is waterfall rolled.
Section 8.1.2 - "Up" Limit Adjustment
If Screen Raises Too High:
1. Lower screen surface approx.
1' below desired setting and
turn off.
2. Turn UP
(II)
limit screw clockwise
(3 screw turns =
1
/
roller
2
revolution).
Caution: DO NOT allow dowel to wrap over roller when operating screen! This could damage screen.
Section 8.2 - ILT Motors with Internal Low Voltage Control Limit Adjustments
Please Note: Hold STOP button for 3-5 seconds while in programming
mode to reverse motor direction.
Please Note: When ordering a motor with internal Low Voltage
Controller, if case ships separately from contents, case
includes 25' cable and special low voltage switch.
1. Connect ILT switch to motor via terminal blocks, or via modular port
using four conductor modular cable. When using modular cable,
cable connectors MUST NOT be crimped in reverse, as with standard
telephone cable.
(For Dry Contacts Wiring Diagram, see Section 12.)
2. Set slide switch to lower position. Hold DOWN button to move viewing
surface to desired lower limit. If screen moves in opposite direction,
release DOWN button and hold STOP button for 4 seconds. This
reverses operation of UP and DOWN switches.
3. Move slider switch into center position. Wait several seconds.
Please Note: Move slider switch from down to up in one motion to set
limits in same position.
4. Set slide switch to higher position. Move viewing surface to desired
upper limit by holding UP button on wall switch.
5. Return slide switch to center position to return to normal operation.
6. To set viewing surface to alternate format position, move viewing
surface to desired position and press STOP button. Hold STOP button
for at least 3 seconds to record position.
(II)
limit screws are reversed
(Fig.
9).
(requires a
5
/
" (4 mm) Allen wrench)
32
To Increase Screen Drop:
1. Lower screen to down limit.
2. With down switch on, turn DOWN
screw counterclockwise
/
roller revolution)
to increase drop.
1
2
3. Test by raising screen approximately
1'
(30 cm)
then down to new down limit.
4. Repeat steps 2 and 3 until desired
position reached.
3. Test by advancing screen up.
4. Repeat steps 1 through 3 until
desired position is reached.
Caution:
- Be sure all switches are in "off" position before adjusting limit switches.
- Be prepared to shut off manually while testing.
- Screen may be damaged by lowering it too far and exposing roller.
- Motor must be installed so limit switches are pointed down.
Figure 9
Motor
End
n c
(I)
limit
d i e
(3 screw turns =
e
A u
S i d
Standard Roll
Left hand motor:
White Socket—Down
Yellow Socket—Up
Right hand motor:
White Socket—Up
Yellow Socket—Down
If Screen Needs to Raise Higher:
1. Lower screen surface
approx. 1' below
desired setting and
turn off.
Please Note: Press and release UP button on switch to move screen to upper
limit. Press and release DOWN button to move screen to lower limit.
• While motor is in motion, press STOP button for less than 2 seconds to
stop viewing surface at present position.
• Once motor is stopped, press STOP button to move viewing surface to
FUNCTION
POSITION
alternate format position.
• Hold STOP button, when motor is at rest or in motion, for 3-5 seconds to
Set LOWER limit
DOWN
record new alternate format position.
• Hold STOP button for 3-5 seconds while in programming mode to reverse
Set UPPER limit
UP
motor direction.
Normal Operation
CENTER
Back View of Wall Switch
To Motor
with
Internal
Low Voltage
Slide
Switch
C
o
m
+
m
5V
o
To Motor
DC
n
with
Internal
Low Voltage
page 5 of 7
Motor
Motor
End
End
e
c k
B a
d e
S i
Reverse Roll
Waterfall Roll
Left hand motor:
Left hand motor:
White Socket—Down
White Socket—Up
Yellow Socket—Up
Yellow Socket—Down
Right hand motor:
Right hand motor:
White Socket—Up
White Socket—Down
Yellow Socket—Down
Yellow Socket—Up
2. With Up switch on,
3. Repeat steps 1 and 2
turn UP
(II)
limit screw
until desired position
counterclockwise
is reached.
(3 screw turns =
1
/
2
roller
revolution).
POSITION
FUNCTION
DOWN
Set LOWER limit
UP
Set UPPER limit
CENTER
Normal Operation
D
Please Note: 5V DC must
o
U
w
p
be connected to be able
n
to set limits using wall
switch.
e
n c
d i e
A u
e
S i d