Juga untuk Draper Premier: Petunjuk Pemasangan & Pengoperasian (2 halaman), Petunjuk Pemasangan & Pengoperasian (2 halaman), Petunjuk Instalasi (2 halaman), Petunjuk Pemasangan & Pengoperasian (7 halaman), Petunjuk Instalasi (4 halaman), Petunjuk Instalasi (2 halaman), Petunjuk Pemasangan & Pengoperasian (4 halaman), Panduan Petunjuk Pemasangan & Pengoperasian (7 halaman)

Draper Premier Petunjuk Instalasi
Premier Electric Projection Screen by Draper
Read instructions through completely before proceeding.
Follow instructions carefully. Installation contrary to instructions
invalidates warranty.
Screen should be accessible for complete removal should fabric
become damaged or should other service be required.
Screen should be installed level (using a carpenter's level).
Nothing should be fastened to screen dowel or viewing surface.
Operating switch(es) packed separately in screen carton. Do not
discard with packing material.
Screen operates on 110-120v, 60 Hz. current.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Hanging Screen
General:
When locating viewing surface and checking clearance for screen's operation,
remember surface is centered in case. Handle case carefully to protect finish.
Regardless of mounting method, screen should be positively and securely
supported so that vibration or even abusive pulling on the viewing surface will
not cause case to work loose or fall. Installer must insure that fasteners used
are of adequate strength and suitable for the mounting surface chosen.
Suspended Installation:
Suspend screens from holes in endcaps as shown. "S" hooks are included
with screen. Chains (or cable) and turnbuckles should be provided by installer.
Chains should be attached to beams or other structural members.
Turnbuckles should be adjusted so screen hangs level.
Wall Installation:
Mount screen through holes in back of endcaps as shown. No. 12 screws for
wood or aluminum are provided. However, if screen attaches to plaster,
gypsum board or masonry, installer should furnish toggle bolts, molly bolts,
nylon or lead anchors as required.
Recessed Installation:
Recess should permit access for removal of screen if necessary. Screen
may be mounted as in suspended or wall installation. Optional ceiling slot
kit also available; see diagram on page 2 and separate instruction sheet
(included with ceiling slot kit).
Electrical Connections
Screen operates on 110-120v, 60 Hz. current. Junction box is located inside
left endcap and cover plate is secured to endcap with two screws. Junction
Copyright © 2003 Draper, Inc.
Installation Instructions
Caution
Optional
ceiling slot
kit also
available;
see page 2
for diagram
Form Premier_Inst03
Printed in U.S.A.
box contains terminal strip, per wiring diagram on reverse.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire connecting screen to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in accordance
with wiring diagram supplied, and wiring should comply with national and local
electrical codes.
All operating switches should be "Off" before power is connected.
Operation
CAUTION—Important Instructions: Shipping support brackets must be
removed from each end of dowel during initial operation, before screen is
operated in UP direction. After screen is installed, lower viewing surface to
access screws holding brackets to dowel. Loosen hex head screw, remove
bracket and retighten screw at each end of dowel. Raise and lower viewing
surface several times to confirm satisfactory operation. If viewing surface does
not operate properly, turn power off and check electrical connections.
Dowel
110-120v Single Station Control— 3-position up-off-down switch permits
operation to be stopped at any point. Factory adjusted limit switches
automatically stop screen when fully down or fully up.
110-120v Multiple Station Control —Switches are similar in appearance to
110-120v Single Station Control. Screen stops when switch is released and
may be restarted in either direction. Factory adjusted limit switches stop
screen automatically when fully up or fully down.
24v Control —Three-button up-stop-down switch(es) stop at any point
desired, operate in any sequence. Factory adjusted limit switches
automatically stop screen when fully up or fully down.
Key Operated Switching —Two kinds of key-operated switches are optionally
available with this unit. ➀ The key-operated power supply switch controls
power to the screen and switches. When it is "off", the switches will not
operate screen. Key may be removed from the switch in either "on" or "off"
position. ➁ A three-position key switch permits the screen to be operated
directly by key. In this case, the screen's operator must always have a key.
Screen has been factory set and should not normally require further
adjustment. However, if you desire to change the "up" and "down" stopping
positions, proceed as follows:
CAUTION: Be sure all switches are in "off" position before adjusting limit
switches. Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
Adjusting "fully up" position — "Up" stopping position may be adjusted by
turning the yellow limit switch adjustment socket. The yellow socket is located
on left end of screen roller and is accessible to a screwdriver/Allen wrench
(4mm or
5
/
"). Turning the socket counterclockwise will allow the viewing
32
surface to retract farther into the case. Turning it clockwise will cause the
surface to stop farther out of the case. One full revolution of the socket will
alter the stopping position of the viewing surface by approximately 1
Adjusting "fully down" position — "Down" stopping position may be
adjusted by turning the white limit switch adjustment socket. The white socket
is located on the left end of screen roller and is accessible to a screwdriver/
5
Allen wrench (4mm or
/
"). Turning the socket counterclockwise will allow the
32
viewing surface to run farther down. Turning it clockwise will shorten viewing
surface, causing it to stop in a less extended position. At no time should
viewing surface be unrolled enough to expose any part of screen roller.
Please Note: Instructions for adjusting Draper's Tab-Tension
System for Series/V screens are on page 2.
Shipping
Bracket
Adjustments
1
/
".