Draper Ultimate Access Series Petunjuk Pemasangan & Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Petunjuk Pemasangan & Pengoperasian untuk Layar Proyeksi Draper Ultimate Access Series. Draper Ultimate Access Series 4 halaman. 220v ultimate access electric projection screen
220V Ultimate Access by Draper
Single Station Control
See separate Serial
Communication-RS232
Instruction sheet for
enabling RS232 with
the MC1.
Wiring Diagrams
CE Approved
Terminal strip in
junction box at left
end of screen
Control
switch
Dashed wiring
by electrician
230V,
50 Hz.
Low Voltage & Wireless Control
Program LED
Fuse
MC1
www.draperinc.com
Multiple Station Control
Not CE Approved
Terminal strip in
junction box at left
end of screen
Cap off with wire
nut & tape
Blue
Red
Black
Blue
Red
Black
Red
Blue
Black
Dashed wiring
PE
by electrician
230V, 50 Hz.
Red-to screen (directional)
Brown-to screen (directional)
White-Common to screen, 230V AC
Black-to 230V AC
Yellow-to 230V AC
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Switch For more than one of these,
a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional
LVC-III modules (up to six total-
connect from Aux to Eye).
MC1
Red-to Screen (directional)
Black-to Screen (directional)
Blue-Common
Brown-Hot to 230V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver
or LED Wall Switch, a Splitter and a
Power Supply is required. Plug RF
Receiver or LED Wall Switch and
Control
Power Supply into splitter, then run
Switches
cable from Splitter to MC1 Eye Port.
24v DC
(765) 987-7999
Terminal strip in
junction box at left
end of screen
All-Pole Disconnect
by Others
STOP
STOP
230V, 50 Hz.
Control
Switches
24v DC
Terminal strip in
junction box at left
end of screen
All-Pole Disconnect
by Others
STOP
STOP
230V, 50 Hz.
Page 4 of 4