Draper Ultimate Access XL V Petunjuk Manual - Halaman 7
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Layar Proyeksi Draper Ultimate Access XL V. Draper Ultimate Access XL V 7 halaman. 220v electric projection screen
Juga untuk Draper Ultimate Access XL V: Petunjuk Pemasangan & Pengoperasian (7 halaman)
Ultimate Access XL E & V
Electric Projection Screen
Section 13 - Wiring Diagrams: 110-120V Motor and Quiet Motor
Please Note: Do not wire motors in parallel.
Single Station Control
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
Dashed wiring
by electrician
by electrician
Control
Single gang box by others
Control
switch
switch
1
Min. 4" x 2
/
" x 1
8
Blue
Blue
Red
Red
Black
* These wiring
Location of key
Location of key
diagrams are for
operated on-off
operated on-off
switch if furnished
switch if furnished
Access screens with
motor on audience
left (standard), and
To 110-120V Line
To 110-120V Line
fabric unrolling from
the back of the roller
(standard).
Internal LVC-IV - Single or Multiple Projection Screen Wiring Diagram
INTERNAL SCREEN WIRING
Green/Yellow
(Motor Ground)
Red (Up)
Black (Down)
White (Common)
GND
N
To
110-120 VAC
L1
Line
External LVC-IV - Single or Multiple Projection Screen Wiring Diagram
INTERNAL SCREEN WIRING
White (Common)
Red (Up)
Black (Down)
Green/Yellow
(Motor Ground)
To
110-120 VAC
L1
Line
N
GND
Multiple Station Control
Multiple Station Control
Internal Screen Wiring
Internal Screen Wiring
White (Common)
White (Common)
Black (Down)
Black (Down)
Red (Up)
Red (Up)
Green (Ground)
Green (Ground)
Cap off with wire nut and tape
Red
Blue
Red
Single gang box by others
7
1
7
/
" deep
Min. 4" x 2
/
" x 1
/
" deep
8
8
8
Dashed wiring
Black
by electrician
Black
Red
Blue
Red
Black
Red
Blue
Red
Single gang
Black
Black
box by others
Min. 4" x 2
Location of key
Location of key
3 shown. More or less
equally feasible.
operated on-off
operated on-off
switch if furnished
switch if furnished
To 110-120V Line
To 110-120V Line
Internal LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
Green/Yellow (Ground)
Red-to screen (directional)
Brown-to screen (directional)
White -Common to screen & 110V-120V AC Neutral
Yellow-to 110V-120V AC-Hot
Black-to 110V-120V AC-Hot
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
Factory wiring
External LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110V-120V AC-Hot
Black-to 110V-120V AC-Hot
White-Common to screen & 110V-120V AC Neutral
Green/Yellow (Ground)
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
Factory wiring
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Cap off with wire nut and tape
Blue
Dashed wiring
Black
by electrician
Blue
Black
Blue
Single gang
box by others
1
/
" x 1
7
/
" deep.
Min. 4" x 2
1
/
" x 1
7
/
" deep.
8
8
8
8
3 shown. More or less
equally feasible.
Receiver
Button
Receiver
Button
page 7 of 7
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
Wall Switch
IR Eye Input
*A maximum of six (6)
Low Voltage
LVC-IV modules can be
Trigger
linked together.
4-28 VDC
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
Wall Switch
IR Eye Input
*A maximum of six (6)
Low Voltage
LVC-IV modules can
Trigger
be linked together.
4-28 VDC