Draper 77759 Petunjuk Manual - Halaman 12
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Kompresor Udara Draper 77759. Draper 77759 16 halaman. 25 & 50 litre compressors
USE ONLY ORIGINAL SPARE PARTS, AVAILABLE AT ALL AUTHORIZED SERVICE CENTRES.
FAULT
Pressure drop in tank
The pressure switch
valve leaks when the
compressor is idle
The compressor
stopped and does not
start
The compressor does
not stop even though
the max. pressure
allowed has been
reached; the safety
valve operates
The compressor does
not get to the set
pressure and
overheats
The compressor is
noisy with metallic
clangs
TROUBLESHOOTING
POSSIBLE CAUSE
Air leaks at connections
Non-return valve seal defective
Overload cut-out tripped
Incorrect Setting
Compressor head gasket broken
or valve faulty
Bearing or connecting rod
seizure
Allow the compressor to reach max.
pressure allowed. Switch it of and brush
a soapy water solution onto all air
connections. Look carefully for air bubbles
flowing out. Tighten those connections
where leaks are present.
If the problem is still present, contact the
After Sales Service.
Contact your Local Service Centre
See Page 8
Contact your Local Service Centre
Contact your Local Service Centre
Contact your Local Service Centre
- 11 -
REMEDY