Drawmer 1969 Panduan Operator - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Operator untuk Peralatan Perekaman Drawmer 1969. Drawmer 1969 13 halaman. Dual vacuum tube compressor
Juga untuk Drawmer 1969: Panduan Operator (13 halaman)

8
Bass EQ:
Treble EQ:
Gain:
Low/High:
Flat/EQ:
Norm/Bright:
QUICK SET UP
Select Stereo Link mode for use with a stereo signal, otherwise ensure
this switch is Off.
Choose correct signal source for each channel using selector.
Initially, set the Attack selector to 3 (a Medium position) and set Release
to 6 (Programme Dependent).
Set the Mode switch to Normal and the Meter switch to GR.
With programme material playing, adjust the Threshold control until the
desired amount of gain reduction registers on the meters.
Use the Output Gain control to restore any level lost due to compression.
If necessary, change the Attack and Release settings to suit the material.
Passive equaliser control, which can be set to provide up to
15dB of bass boost at 40Hz.
Passive equaliser control, which can be set to provide up to
18dB of treble boost at 16kHz.
Provides up to 30dB of gain at the Low Gain switch setting
or 40dB at the High Gain setting.
Sensitivity selector switch. Adds 10dB of gain in the High
position.
Switches the equaliser controls out of circuit when a flat
response is required, or for 'A/B' comparison of EQ
effectiveness.
Switches in 10dB of boost at 2kHz in the Bright position, (
when 'EQ' has been selected on the Flat/EQ switch.)
1969 OPERATORS' MANUAL