Drawmer 1977 Panduan Memulai Cepat

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Peralatan Perekaman Drawmer 1977. Drawmer 1977 2 halaman. Channel strip
Juga untuk Drawmer 1977: Panduan Operator (12 halaman)

Use a fast Attack (0.2mS - 100mS) to catch transients, mid speeds to control the dynamics and slow for buss
compression and drums. Release (0.05S - 2S) settings should be slow enough not to cause pumping, but fast
enough that attenuation triggered by the last note doesn't linger into the next, this can be automated using the
PGM switch. In addition Big & Air switches are included that alter the compressor side chain to thicken the low
end and add vibrancy to the high end. Above a Gain Reduction Meter shows how many dB's the signal has been
attenuated by.
A Saturate section is located next as part of the compressor stage(see below).
During compression the signal is attenuated so gain may be required to produce the required output level using
the Make Up Gain (-10 to +20dB) control. The amount of gain required in order to bring the signal level to the
same is at input is displayed on the G.R. meter.
A fully hardwired bypass switch toggles the Compressor section to be active or not, and is best used for A/B
comparisons, or to remove the compressor stage from the signal path altogether.
The Saturation circuit is located as part of the compressor stage
and is used to add distortion and warm to a recording. The Saturate
Level (0 to 10) sets the amount of Saturation applied to the signal,
from very subtle, through to warm and to over-driven.
Two switches effect the Type of saturation applied. With both
switches inactive the Saturation control operates throughout the
entire frequency range, however, this can produce unwanted
harshness in the low frequencies and excessive sibilance in the high
frequencies - the
switch when active cuts the low frequencies
prior to the saturation stage, thus reducing the harshness of the
saturation giving a warmer sound rather than over-distortion to the
bass. The same is true of the
switch, it reduces the harshness
of the saturation in the high frequencies, with the effect of far less
sibilance than may otherwise occur.
The combination of variable Saturation plus the Type switches provide absolute control over the amount of
distortion used and allows the engineer to apply either very subtle saturation or to really drive the saturation
whilst still having control over the harshness that may occur.
VU METER & OUTPUT
A backlit moving coil VU Meter monitors the level of the output signal, this has a Pad switch that adjusts it to
show either normal output level or, for those working at 'hot' output levels, VU +10dB.
The overall EQ/compression/saturation of the signal can be altered using the Mix control by adjusting an
amount of the original signal (dry) with the EQ/compressed/saturated signal (wet) in an effect similar to
'parallel compression', and, in addition, a single Fade (Off to +12dB) control modifies the output. Adjust this
to fade out the signal or so that the output signal approaches the desired level only on signal peaks.
Finally a fully balanced hard-wire Preamp Direct switch connects the preamplifier directly to the output
without passing through the E.Q., the compressor and saturation FET's, or the mix and gain controls at all.
Use this to provide an ultra clean microphone signal or to hear the extent of the effects in an A/B
comparison.
CONTACTING DRAWMER
We will be pleased to answer all questions to enhance your usage of DRAWMER equipment.
Please address correspondence to:
DRAWMER Electronics LTD
Coleman Street
Parkgate
Rotherham
Further information on all Drawmer products, dealers,
South Yorkshire
Authorised service departments and other contact
S62 6EL
United Kingdom
information can be found on our website: www.drawmer.com
This Quick Start Guide is copyrighted © 2023 Drawmer Electronics Ltd.
All rights reserved. Under copyright laws, no part of this publication may be reproduced, transmitted, stored in a retrieval
system or translated into any language in any form by any means, mechanical, optical, electronic, recording, or otherwise,
without the written permission of Drawmer Electronics Ltd.
SATURATE
Telephone: +44 (0)1709 527574
C
HANNEL
QUICK START GUIDE
Congratulations on the purchase of your 1977 Channel Strip. This quick start guide should provide you with the
very basics to get you started with integrating the 1977 into your studio. More information can be found by
going to the 1977 page on the Drawmer website: www.drawmer.com.
DOWNLOAD MANUAL
Obtain the 1977 Operator's Manual at
https://www.drawmer.com/uploads/manuals/server2/1977_operators_manual.pdf
or scan the code to the left using a QR scanner app on your mobile device.
PRODUCT REGISTRATION
Register your 1977 at
https://www.drawmer.com/register.php
or scan the code to the left using a QR scanner app on your mobile device.
S
TRIP
DRAWMER