Anomaly
Description
Machine indicates that Inlet air over heat protection
12:1
has cut out
Machine indicates that Outlet air over heat protection
12:2
has cut out
12:8
Machine indicates that condense water tank has
(for condense
not been drained within set time
models)
12:11 (for models
Machine indicates garment is not dry within max drying
with RMC system)
time (RMC)
12:12 (for models
Machine indicates garment is not dry within max drying
with RMC)
time (AUTOSTOP)
12:13 (for models
Machine indicates garment is not dry within max drying
with RMC)
time (TIME)
12:14
Machine indicates flame sensor is not detecting gas
(for gas models)
flame within set time
Machine indicates vacuum switch is not activated
12:15
within set time
Machine indicates vacuum switch has deactivated
12:18
several times during program run
12:19 (Heat Pump
Machine indicates blocked air flow in heat pump unit
models)
12:253
Machine indicates that Jumper 1 is missing
17:20 (Heat Pump
Machine indicates critical error in heat pump unit
models)
17:21 (Heat Pump
Machine indicates internal error in heat pump unit
models)
20:1
Machine indicates drum motor is overheated
30:1
Machine indicates fan motor overheated
Instructions to User
Switch off power to the machine and contact authorized service
Push the control knob to restart the program
1. Turn the machine off and on again. Condensate pump will start
2. If water is coming out of the condensate drain hose, it might be
partly blocked. Contact authorized service
3. If the pump is running and no water coming out the drain is
blocked. Contact authorized service
1. Check that the dryer is not overloaded
2. Open the door to reset the error message
1. Check that the dryer is not overloaded
2. Check that the garments are not loaded too wet after extraction)
3. Open the door to reset the error message
Open the door to reset error message
Reset the error message by a short push on the control knob
Check the gas supply
Check that machine is not overloaded
Check that Doors are closed and seals are in good order
Press the control knob to clear error message and restart program
Redistribute the load in the drum
Press control knob to clear message and restart the program
Clean lint filter
Press control knob to clear message and restart the program
Press control knob to clear message and restart the program
Switch off power to the machine for 5 minutes and then on again
Try to start a new program
Switch off power to the machine for 5 minutes and then on again
Try to start a new program after HP initializing has finished
Wait 30 minutes to allow the motor to cool down
Press the control knob to clear error message
Wait 30 minutes to allow the motor to cool down
Press the control knob to clear error message
Essentia