Problem
The appliance is not in operation. A cook-
ing time is shown in the display.
"Fill water tank" appears even though the
water tank is full
"Fill water tank" appears even though the
water tank is not yet empty, or the water
tank is empty but "Fill water tank" does not
appear
The water tank empties for no discernible
reason. The evaporator dish is overflowing
The evaporator dish has boiled empty
even though the water tank is full.
"Empty tank/Clean?" appears in the dis-
play
There is a "pop" noise during cooking
When you cook with steam, a lot of steam
is created
When cooking with steam, there is again a
lot of steam
Steam escapes from the ventilation slots
during cooking
The appliance is not producing steam
properly
An "E..." fault message appears in the dis-
play
The fault message "E011" appears on the
display
The appliance is not heating. "Demo" is
shown on the display

Replacing the cooking compartment bulb

Heat-resistant 25 W, 220/240 V bulbs, E14 bulb sockets and
the seals are available from the after-sales service. Please
specify the E number and FD number of your appliance.
:
Risk of burns!
Allow the cooking compartment and cooking compartment light
to cool before changing the bulb.
Switch off the fuse in the fuse box or unplug at the mains.
1.
Turn the cover anti-clockwise to remove.
2.
Screw out the bulb by turning it anti-clockwise and replace
3.
with a bulb of the same type.
Possible cause
The rotary selector was accidentally oper-
ated
The
button was not pressed after mak-
n
ing the setting
The water tank has not been inserted
properly
The detection system is not working
The water tank is dirty. The mobile water
level indicators are jammed
The water tank was not closed properly
The tank lid seal is dirty
The seal in the tank cover is defective
The water tank has not been inserted
properly
The feed line is blocked
The appliance has not been used for at
least two days and the water tank is full
Cold/warm effect with frozen food, caused
by the steam
The appliance is being automatically cali-
brated
The appliance is unable to calibrate itself
automatically if cooking times are too
short
Limescale has formed in the appliance
Technical fault.
A button was pressed for too long or is
jammed
A button combination was actuated
Slide the new seals and the clamping ring onto the glass
4.
cover in the right order.
Screw the glass cover with the seals back on again.
5.
Connect the appliance to the mains and reset the clock.
6.
Never operate the appliance without the glass cover and seals.
Replacing the glass cover or seals
Any damaged glass cover or seals must be replaced. Please
provide the after-sales service with the E number and FD
number of your appliance.
Notes/remedy
Press the
button
%
Press the
button or cancel the setting
n
with the
button
%
Slide in the water tank until it engages.
Call the after-sales service
Shake and clean the water tank. If the
parts cannot be released, obtain a new
water tank from the after-sales service.
Close the lid until you feel it engage.
Clean the seal
Obtain a new water tank from the after-
sales service
Slide in the water tank until it engages
Descale the appliance. Check whether the
water hardness range is set correctly
Empty and clean the water tank. Always
empty the water tank after cooking
This is normal
This is normal
Restore the appliance to the factory set-
ting (see section: Basic settings). Then
start steaming at 100 °C for 20 minutes
This is normal
Start the descaling programme.
Press the
0
button to delete the error
message. Reset the clock if required.
If the error message appears again, call
the after-sales service
Press the
button to clear the fault mes-
0
sage. Press all of the buttons individually
and check if they are clean
Disconnect the power supply and recon-
nect it after 10 seconds. Within 2 minutes,
press the
button for 4 seconds
D
19