Alemlube EL SERIES Buku Petunjuk - Halaman 7

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pompa Air Alemlube EL SERIES. Alemlube EL SERIES 17 halaman. Oil pump
Juga untuk Alemlube EL SERIES: Petunjuk Servis (3 halaman), Panduan Teknis Pemilik (4 halaman), Panduan Teknis Pemilik (6 halaman), Panduan Teknis Pemilik (11 halaman), Petunjuk Servis (2 halaman), Petunjuk Servis (2 halaman), Panduan Teknis Pemilik (4 halaman), Panduan Teknis Pemilik (2 halaman), Panduan Teknis Pemilik (4 halaman), Panduan Teknis Pemilik (5 halaman), Panduan Pemilik (4 halaman)

Alemlube EL SERIES Buku Petunjuk

Details of Operation

1. Before putting into operation
Check the technical data of the installation match with those of the lube meter. For example connections,
pressure, flow range and medium. Use the formula: Proper correction factor = (actual value / displayed value)
x current correction factor to decide the right connection factor, then set the proper correction factor
(refer to 3. Button usage part)
Once the meter has been installed, please make sure that no air pressure shocks or particles can damage the meter
Please check all connections to avoid leakage
2. Change the battery
Battery type: Lithium CR2, 3V/1400mAh
Last for 8 years of operation, corresponds to approximately. 500,000 litres
Change the battery like below when the battery signal is flashing on the display
Remove the protector cover, unscrewing the screw
Change the battery and screw the lid on again
3. User buttons
The turbine digital meter features two buttons (MOVE and RESET) which individually perform two main functions
and together, other secondary functions
The main functions performed are:
For the reset key, resetting the partial Register and reset table total (reset total)
For the move key, entering instrument calibration mode
Used together, the two keys permit entering configuration mode

4. Battery replacement

When replacing the battery, please open the cover, remove the plug and replace the battery.

LCD Display

KEY
Partial register (5 figures with moving comma from 0.1 to 99999)
Indicating the volume dispensed since the reset button was last pressed.
Indication of battery charge
Indication of calibration mode
Indication of resetting present total to Zero
Total register
Indication of flow rate mode
Indication of unit of measurement of partial:
L = Litres
GAL = Gallons
PT = Pints
QT = Quarts
NSW/ACT
QLD/PNG
TEL: (02) 9939 0711
TEL: (07) 3889 8480
FAX: (02) 9939 0411
FAX: (07) 3889 8490
OWNER'S TECHNICAL MANUAL
Oil Transfer Kit with Meter & Trolley
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
Visit our website at
www.alemlube.com.au
WA
SA/NT
TEL: (08) 9209 3066
TEL: (08) 8241 7111
FAX: (08) 9209 3933
FAX: (08) 8241 7011
or
www.alemlube.co.nz
O30060
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008
7