The manufacturer explicitly emphasises the necessity of being particular in testing the tightness
of the heating circuit (radiators, piping joints, floor heating, etc.) with the connection of the
storage tank. No pressure grow above the maximum operating pressure of 0,3 MPa in the
storage tank heating water compartment may occur, if the heating system is pressurised to
higher than the maximum operating pressure, the inner stainless exchanger may get
permanently damaged!
No stop fitting can be put between the security fitting of the heating circuit and the storage
tank!!!
1.3 TECHNICAL PARAMETERS
STORAGE TANK CAPACITY [l]
INNER TANK CAPCITY [l]
WEIGHT [kg]
HEATING SURFACE OF THE
STAINLESS EXCHANGER [m2]
HEATING SURFACE OF THE
EXCHANGER [m2]
MAXIMUM PRESSURE [MPa]
MAXIMUM PRESSURE OF
STAINLESS EXCHANGER [MPa]
MAXIMUM PRESSURE OF
EXCHANGER [MPa]
MAXIMUM TEMPERATURE OF
WATER IN THE TANK [°C]
MAXIMUM TEMPERATURE OF
WATER IN THE EXCHANGER [°C]
AMOUNT OF HOT WATER AT
40°C AT WATER TEMPERATURE
OF 53°C IN THE STORAGE TANK
/HW FLOW RATE [l/(l/min)]
AMOUNT OF HOT WATER AT
40°C AT WATER TEMPERATURE
OF 80 IN THE STORAGE TANK
/HW FLOW RATE [l/(l/min)]
MAXIMUM OUTPUT OF EL.
HEATING ELEMENT OF TJ 6/4"
SERIES [KW]
ENERGY EFFICIENCY CLASS
STANDING LOSS [W]
* value stated by calculation
NADO 300/20 v6
NADO 500/25 v6
320
20
106
4,5
1,6
0,3
0,6
1
90
110
*210 / 10
*520 / 10
2 x 4,5
C
80
NADO 750/35 v6
475
23
134
6,25
2,2
0,3
0,6
1
90
110
*260 / 10
490 / 10
*650 / 10
1170 / 10
2 x 6
C
91
NADO 1000/45 v6
772
999
32
37
165
197
8,5
10
2,2
3,3
0,3
0,3
0,6
0,6
1
1
90
90
110
110
*750 / 10
*1450 / 10
2 x 6
2 x 6
C
C
114
148
- 5 -