Drazice OKCE 750 S/1 MPa Panduan Pengguna - Halaman 14
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Pemanas Air Drazice OKCE 750 S/1 MPa. Drazice OKCE 750 S/1 MPa 15 halaman.
13. FURTHER INFORMATION
Notice: 300-1000 litre capacity heaters are screwed onto the bottom wooden palette with M12 screws. When the heater is
released from the palette and prior to its putting into operation, 3 adjustable legs supplied as the product accessories have
to be installed. With these legs, the heater may be positioned vertically to the base, within 10 mm.
Disposal of packaging material and functionless product
A service fee for providing return and recovery of packaging material
has been paid for the packaging in which the water heater was
delivered.
The service fee was paid pursuant to Act No. 477/2001 Coll., as
amended, at EKO-KOM a.s. The client number of the company is
F06020274. Take the water boiler packages to a waste disposal place
determined by the town. When the operation terminates, disassemble
and transport the discarded and unserviceable heater to a waste
recycling centre (collecting yard), or contact the manufacturer.
14. FUNCTIONAL DEFECTS
Defect
1
Water in the tank is cold
2
Water in the tank is not warm enough
3
Water in the tank is cold
Water in the tank does not correspond with
4
temperature set
* Each heating element is made of two or more parallel connected coils. The element works but on lower output.
Do not try to repair the failure yourselves. Seek either expert or service help. It does not take much for an expert to
remove the defect. When making a repair appointment, report the type and serial number you find on the performance
plate of your water heater.
Control light
- Heating element failure
is on
- Some elements are not heating
- Failure of one of the elements
is on
- Failure of one of the heating coils in the element *
- Thermostat failure
is not on
- The safety fuse turned off electricity supplye
- Power supply outside the heater discontinued
is on
- Thermostat failure
14
Failure