Juga untuk Drazice OKC 160 NTR / BP: Panduan Pengoperasian dan Pemasangan (17 halaman), Panduan Pengoperasian dan Pemasangan (12 halaman), Panduan Pengoperasian dan Pemasangan (20 halaman), Panduan Pengoperasian dan Pemasangan (18 halaman), Panduan Pengoperasian dan Instalasi (20 halaman), Panduan Pengoperasian dan Pemasangan (18 halaman), Panduan Pengoperasian dan Instalasi (13 halaman)

Drazice OKC 160 NTR / BP Panduan Pengoperasian dan Pemasangan
To limit regulation
off the thermostat knob (it will be tough at first) and you will find two cylindrical pins Ø2,15mm on
-
the back side of the knob
pull off one pin and insert it to the corresponding hole of the selected maximum temperature.
-
put the knob back on (to the stop).
-
To block the setting
set the selected temperature pull off the thermostat knob without changing the setting, there are
-
two pins on the back side of the knob
Pull off both of them and fit them to the holes corresponding with the selected temperature so that
-
the gap between the pins was without a hole, and the position was opposite the set temperature.

4 IMPORTANT NOTICES

4.1 INSTALLATION REGULATIONS

Without a confirmation of performed electrical installation issued by an authorised company, the
-
warranty certificate shall be void.
Check and exchange the Mg anode regularly.
-
You have to apply for approval of a local power supplier to connect the heater.
-
No stop valves can be put between the heater and the safety valve.
-
If the overpressure in the water main exceeds 0.48 MPa, a pressure control valve must be mounted
-
before the safety valve.
All hot water outputs must have a combination faucet.
-
Before filling the heater with water for the first time, it is recommended to fasten the flange
-
connection nuts of the tank.
It is not allowed to handle the thermostat, aside from temperature resetting with a control button.
-
All electric installation handling, adjustment and replacement of the regulation elements shall only
-
be performed by an authorised service company.
The thermal fuse must not be turned off! In case of thermostat defect, the thermal fuse interrupts
-
electric power input to the heating element if the water temperature in the heater exceeds 90 °C.
As an exception, the thermal fuse may also switch off due to water overheating caused by
-
overheating the hot water heating system boiler (in case of a combined heater).
We recommend you operate the heater with one type of energy.
-
Both the electric and water installation must follow and meet the requirements and
regulations relevant in the country of use!
Figure 9
- 19 -