Bosch Vision 800 Series Panduan Servis - Halaman 32
Jelajahi secara online atau unduh pdf Panduan Servis untuk Oven Bosch Vision 800 Series. Bosch Vision 800 Series 43 halaman. Gas slide-in ranges
Juga untuk Bosch Vision 800 Series: Petunjuk Penggunaan Manual (40 halaman), Dimensi dan Spesifikasi (2 halaman), Panduan Instalasi (6 halaman), Panduan Petunjuk Instalasi (28 halaman), Panduan Servis (36 halaman)
58300000202443_ARA_EN_C
Error Code
Description
Wrong module code
E000
(E100/E400 internal errors
reported as E000)
E302
Control module too hot
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
JANUARY 2018
Cause/Notes
Control module and user interface are
mismatched. No operation is possible.
Temperature sensor on the control module
detects temperature higher than limit value.
Control turns off heating elements and fan
defaults to high speed. When cavity
temperature lowers to 212°F/100°C, heating
will resume and error will be cleared. (If self-
clean was running, it will be disabled until a
control reset is performed.)
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
Service Manual for Bosch 800 Series Built-in Wall Ovens
Suggested Action(s)
Enter correct option code in Service mode.
If cooling fan is not operating...
Check connections to the fan and the
control module (see Small Load Schematic).
If cooling fan is operating...
Check element operation
Check for air obstruction or damaged
upper/lower ventilation trims
Check for stuck relays.
Page 32 of 43
800 944-2904