CARLO GAVAZZI SMSA2P02 Panduan Pengguna - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Sensor Keamanan CARLO GAVAZZI SMSA2P02. CARLO GAVAZZI SMSA2P02 16 halaman. Safety magnetic sensors, coded magnetic units

CARLO GAVAZZI SMSA2P02 Panduan Pengguna
PARAMETERS
Function
D-ON (mm)
D-OFF (mm)
D-RESET (mm)
Switching V max
Switching I max
Switching P max
Max continuous I
Connection
(1)
Due to a 39 Ohm, 2 W series-connected resistor.
(2)
Two N.O. series-connected contacts
PARAMETERS
Function
D-ON (mm)
D-OFF (mm)
D-RESET (mm)
Switching V max
Switching I max
Switching P max
Max continuous I
Connection
(1)
Multiple flux coded.
(2)
The BROWN and WHITE wires are short-circuited
SMS-02/S1
1 N.O. + 1 N.C.
20 ± 3
30 ± 5
35 ± 5
N.O.
N.C.
100 Vac 100 Vac
0.25 A
0.25 A
5 VA
5 VA
(1)
0.2 A
1.0 A
4x0.15 mm
SMS-A2P- 02
1 N.O. + 1 N.C.
15 ± 4
20 ± 6
25 ± 7
2
4x0.15 mm
SMS-10/NC
(2)
1 N.O.
1 N.C.
(Safety)
(Signal)
20 ± 3
17 ± 5
22 ± 3
21 ± 5
22 ± 3
21 ± 5
100 Vac
0.25 A
5 VA
1.0 A
PVC cable, 2m
2
SMS-A2P-10
(1)
1 N.O.
16 ± 4
20 ± 6
20 ± 6
100 Vac
0.25 A
5 VA
1.0 A
PVC cable, 2m
2
2x0.35 mm
SMS-10
1 N.O.
20 ± 3
22 ± 5
22 ± 5
2
2x0.35 mm
SMS-A2P-30
SMS-A2P-30/S2
(2)
2 N.O.
16 ± 4
20 ± 6
20 ± 6
2
4x0.15 mm