CLS.. unit is misaligned (with null
distance between sensor and
magnetic unit) along the r
direction (see Technical Data) if
their axis are always parallel.
4.
INSTALLATION
4.1
Warnings
The safety sensor and the relative
coded magnetic unit must be
installed according to the
standards in force in the country
of use, when the machine is not
powered and with no dangers for
the operator.
It is recommended to keep the
connection cables separate from
power supply loads cables of
other devices.
Ensure that there are no
conductors, cables or loose
materials that can come into
contact with the sensor and/or
with the coded magnetic unit.
Ensure that the conductors are
not excessively tight, that their
positioning avoids potential cuts
or squashing and that they are not
in the way of people or things.
Ensure that the machine can
operate according to all the
technical data in this manual.
Avoid installation during storms.
Do not dispose of the packaging
in the environment.
4.2
Wiring
The CLS.. coded magnetic unit
must be mounted on the moving
Fig. 6: Example of application on
hinged guard
guard of the machine, and the
SMS.. magnetic sensor must be
fixed on a stationary part of the
machine.
All the screw and nuts must be
properly clamped; the position of
the SMS.. sensors must avoid any
possibility for the operator to
reach dangerous parts of the
machine.
The connections of all the SMS..
sensors are listed in Table 1; the
pin-out of the connectorized
models is shown in Fig. 7 and 8.
Fitting the sensor and/or the
magnetic unit directly on
ferromagnetic parts (or very close
to ferromagnetic parts), would
lead to a reduction of the
operating distances.
It is recommended to fit the
sensor and/or the coded magnetic
unit on non ferromagnetic parts.
If fitted on ferromagnetic material,
it is necessary to place a non
ferromagnetic material (min.
thickness of 6 mm) between the
7