Juga untuk Carmanah G Series: Panduan Memulai Cepat (16 halaman), Manual (11 halaman), Manual Penggantian Sistem Manajemen Energi (12 halaman), Manual Penggantian Pintu Kabinet (10 halaman), Manual (9 halaman), Panduan Pengguna (18 halaman), Manual (10 halaman), Manual (10 halaman), Instal Manual (18 halaman)

Carmanah G Series Instal Manual
11. Insert terminal from door switch harness into Position 2 of AI harness connector. Orient terminal same
way as other terminals present in connector. Tug to confirm it's fully inserted. Cable ties will be tightened
and trimmed at the end of
Connector terminal shown uncrimped. Crimp wings will be bent over wire strands.
4.3

AI 500-070 Field Control Unit (FCU)

1. Install two cable tie mounts. Press into ¼" holes.
2. Install the AI harness wires to the terminals as follows:
a. Yellow → PV+ (over existing terminal)
b. Violet → INPT+
c. Blue → OUT1
d. Red → DC+
e. Black → DC-
3. Secure yellow wire to mounts & location shown with three cable ties. Leave loose/untrimmed for now.
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 |
Section
4.3.
APPLIED INFORMATION (AI) INTEGRATION
INSTALL GUIDE
10
|
carmanah.com