Juga untuk Carmanah R247-G: Panduan Memulai Cepat (16 halaman), Manual (11 halaman), Manual Penggantian Sistem Manajemen Energi (12 halaman), Manual Penggantian Pintu Kabinet (10 halaman), Manual (10 halaman), Instal Manual (14 halaman), Manual (10 halaman), Manual (10 halaman), Suplemen Panduan Pengguna (12 halaman)

Carmanah R247-G Manual
3.2

Installing AC Backplane

Live AC power will be present. Only qualified personnel should carry out the following retrofit.
1. Mount the AC backplane to the four available threaded inserts in the cabinet using the included four
included screws and tighten to snug.
2. Wire the DC output wires from the power supply to the DC Input Power terminal (red wire to RD +, black
wire to BK −).
3. Secure the wires to one of the cutouts on the terminal block plate with a cable tie.
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 |
SOLAR TO AC RETROFIT GUIDE
|
carmanah.com
7