ATI Technologies M1000 Panduan Pengoperasian dan Pemeliharaan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Pemeliharaan untuk Penguat ATI Technologies M1000. ATI Technologies M1000 6 halaman. Dual microphone amplifier
Microphone inputs and outputs use XLR type connectors and require mating
plugs. The applicable input plugs are Switchcraft A3M or equivalent. The output
plugs are Switchcraft A3F or equivalent. Mike wiring is conventional, hi (in phase)
to pin 2, Lo (out of phase) to Pin 3, Shield to pin 1. Either 150 ohm or 50-ohm
microphones can be connected to the MicroAmp without modification.
The MicroAmp M1000 will accept microphone outputs up to 125 mVrms (-14dBm
available power/150 ohms) without distortion.
Output wiring is indicated on the rear panel label. HI outputs are in phase with
each other and with the input signal.
Transformer Output (M1000-1, L1000-1) may have either HI or LO outputs
grounded (but not both).
CAUTION: Balanced differential output (M1000-2, L1000-2) has active drivers for
both HI and LO outputs terminals. DO NOT GROUND either HI or LO terminals.
To drive an unbalanced (one side grounded) Load, connect it between HI and
GND terminals and let the LO terminal float. Two separate 600 ohm unbalanced
loads can be driven from each output without interaction by connecting one
between HI and GND and the other from LO to GND. The two loads thus driven
will be out of phase with each other. Individual grounds are provided for CH l/left
and CH 2/right outputs.
ADJUSTMENTS
The MicroAmp has sufficient gain and output capability to overdrive some
console inputs particularly those providing preamps for high-level input channels.
A -50dBm available power microphone output (2.5 mVrms) will provide +8dBm
output with the gain pot set to two o'clock position. 12 o'clock is approximately
OdBm and 10 o'clock is -10dBm output. Operation with the MicroAmp pot set
below 10 o'clock position degrades noise performance and a fixed attenuator pad
should be placed between the MicroAmp output and the Console input to allow
MicroAmp operation at around 2 o'clock.
MAINTENANCE NOTES
Power supply voltages are + and - 18 VDC nominal, dropping to +/16 VDC under
full output. Maximum allowable voltages are +/- 22 VDC (limited by IC). If zeners
are replaced, remove Al, A2, and A3 ICs and check output voltage before
plugging ICs back into the circuit. Remove power when inserting or removing
ICs.
Audio Technologies Inc. | 154 Cooper Road #902 | West Berlin, NJ 08091 | Voice 856-719-9900 | Fax 856-719-9903 | www.
audio.com