Electrolux Air-O-Chill 727154 Panduan Petunjuk Pengoperasian dan Pemeliharaan - Halaman 15

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian dan Pemeliharaan untuk Pembeku Electrolux Air-O-Chill 727154. Electrolux Air-O-Chill 727154 27 halaman. Blast chiller-freezer 201 (220 lbs.)
Juga untuk Electrolux Air-O-Chill 727154: Lembar Spesifikasi (2 halaman)

Electrolux Air-O-Chill 727154 Panduan Petunjuk Pengoperasian dan Pemeliharaan
C.2 USER INSTRUCTIONS
Before using the appliance, clean the chamber with a detergent
solution, as there may still be condensation in the chamber left
over from the final testing by the manufacturers (see section D.1
for further information).

C.2.1 SWITCHING ON

Switch on the fused disconnet switch or the main circuit breaker
switch and press the I = ON button to start the appliance. The
I = ON indicator light lights up to signal that the appliance is
powered up.

C.2.2 OPERATION

C.2.2.1 Starting a "cruise chilling" cycle
To start the automatic "cruise chilling" (positive) cycle, insert
the core probe in the product and press the button
The cycle starts immediately when activated. To stop it, keep
the button
pressed for at least 3 seconds.
IMPORTANT: The "cruise chilling" cycle is not
activated when the appliance is in "programme selection"
. . . . .
status
C.2.2.2 Selecting a standard cycle
The default setting on the appliance is the SOFT chilling cycle.
Use these buttons
options:
From left to right:
• Positive "SOFT CHILLING"
• Positive "HARD CHILLING"
• Positive "COOLER" maintenance (or preservation)
• Negative "BLAST FREEZING" chilling or freezing
• Negative "FREEZER" maintenance (or preservation)
When choosing a cycle, press the
next option; the options are in a loop and so you can either scroll
forwards
or backwards
to select one of the following
button to move on to the
.
If you want another cycle, keep pressing the
the indicator light for the chosen cycle turns orange, and start it
by pressing the
IMPORTANT:The appliance recognizes automatically when the
food (core) probe is inserted in to the product. If the probe hasn't
been inserted in to the product, a timed cycle will start
automatically.
It is necessary to wait 2 minutes after the end of the preparation
cycle for the automatic recognition (see section below).
C.2.2.3 How to select a "turbo cooling" cycle
To select the "turbo cooling" cycle, press the key
.
LED
will turn orange.
To start the cycle press the key
C.2.2.4 Selecting a program:
First of all, the user has to decide what kind of cycle to launch
(SOFT, HARD, etc.) and then select the program.
Go through the following steps:
• Select the type of cycle;
• Press the program select button
light
lights up.
• press the select button
indicator light
• if the type of program is right, start it by pressing button
if not
• keep pressing the select button
15
button.
.
; the program indicator
until the chosen program
switches on.
until the chosen
button until
; the
.