Figure 6.
Checking/Installing
Exhaust Ducting
The ducting system of the dryer, for optimum
performance, should be as short as possible with a
minimum number of elbows. Your WTA 3500 electric
vented dryer will work best when the venting system
has as few restrictions to the flow of air as possible.
Whether installing to an existing venting system or a
new venting system, make sure that all ducting is
clean and free of lint and does not exceed the length
per elbows as shown in Table 1, below:
Maximum
length of duct
Number
Rigid
Flexible
of Elbows
Duct
Duct
0
30 ft. (914 cm)
20 ft. (610 cm)
1
22 ft. (670 cm)
15 ft. (457 cm)
2
14 ft. (427 cm)
9 ft. (274 cm)
3
6 ft. (183 cm)
4 ft. (122 cm)
Table 1.
Every elbow must have a minimum diameter of 4
inches (10 cm).
The above table assumes the use of an approved
exhaust vent hood with a swing out damper. DO
NOT use an exhaust vent hood with magnetic
latches. To avoid restriction of exhaust the outlet must
be a minimum of 12 inches (30 cm) above ground
level, or any other obstructing surface, as shown
below, in Figure 7.
12" (30 cm) min.
f
Figure 7.
Step 5
Condensate Hose Connection
(Model WTL 5400 Onlyl)
The WTL 5400 must have its condensate drain line
installed and run to a suitable drain. The connection
for the condensate hose is located on the back of the
WTL 5400, see Figure 8.
Figure 8.
The condensate drain hose should already be
connected to the dryer. The other end should then be
placed and secured at a nearby sink or drain, or if
installed with a washer it may, room permitting, be
installed next to the washer drain hose and drained to
the same drain used by the washer.
Be sure to follow all local codes and regulations in
running the condensate to a suitable drain.