SYSTEM DESIGN
Community encourages all system designers that are interested in
incorporating IV6 modular arrays in their venue to use EASE® Focus 3 (EF3) to
model the array. There is a customized version of EF3 that is available from the
Community website that includes Community IV6 GLL data files. In partnership
with Community, AFMG (the maker of EASE software) has developed special
modules that are "Community-exclusive".
The custom Rigging Safety Calculator (RiSC) module (found under the "Loads"
tab) automatically populates and updates in real-time as an array is built and
aimed. Refer to the "IV6 System Design and Installation Manual" for instructions
and explanations about system design with EASE® Focus 3 and array assembly.
ACCEPTABLE MOUNTING POINT LOADING
Use the RiSC module in EASE® Focus 3 to assure mounting point system Safe
Working Load (SWL) and required Safety Factor are not exceeded. The RiSC
module is described on pages 4-5. The system should be modeled in EF3 prior
to ordering, and the system design report generated should be utilized when
installing / assembling the array(s). The software, and system information is
available on the Community website. Use the QR code on the upper right corner
of this page for a link to the IV6 downloads page.
In addition, for sub-behind applications, use the IV6 Sub Behind Hang Point
Calculator" to assure proper deployment of the IV6-SB-AF bracket. It is available
from the IV6 "Downloads" section on the Community website.
INSTALLATION AND ASSEMBLY TIPS
• Test all cabinets before hanging
• Arrange cabinets in the order that they will hang, and loosely attach
appropriate splay brackets to the top of each cabinet
• Preset attenuation settings per the EASE® Focus 3 model on each cabinet
• If using the IV6-SB-AF, adjust the carriage on the array frame to the
suggested pin setting before attaching the loudspeakers
• Orient cabinets so the horns align along the length of the array - this also
aligns the input panels for easy wiring
• Leave splay bracket connections slightly loose until all cabinet connections
are made, then tighten evenly
IMPORTANT: The hex head Grade 10.9 rigging bolts that are used to secure
the splay brackets must also fill any unused holes (at the bottom of a flown
array or at the top and bottom of a ground stack) to seal the enclosure from air
leaks. If those threaded holes are not sealed, air leaks will occur in the enclosure that
will compromise the low-frequency performance with distortion, reduced output, and
premature driver failure.
I SERIES
IV6-LAU Instructions
Scan or click to go to the IV6
downloads section on the
Community website
for the latest
version of this manual.
SAFETY CABLE
The safety cable and associated
hardware
are
not
Consult all applicable codes for
your application. Confer with
a structural engineer for the
appropriate cable/hardware for
the load, application and locale.
If required, the safety cable must
be secured to a suitable load-
bearing point separate from the
array mounting point, with as
little slack as possible, so as not to
develop undue kinetic force if the
primary array mount were to fail.
Light Array Frame
(IV6-LAF-PBB)
When required, a secondary
safety cable can be attached to an
unused hole(s) on the LAF.
GlidePoint™ Array Frame
(IV6-GP-AF)
A secondary safety cable
mounting point is available from
PolarFocus.
Part number: RLP-X2-1800
Sub Behind Array Frame
(IV6-SB-AF)
Contact PolarFocus, for a
quote for a custom secondary
attachment point(s) required for
your particular application.
included.