Remove the water pipe from the cover.
Then, remove the condenser fan scroll.
Now, it is easy to repair the refrigerant system.
Service manual for K1 portable Series
4.10 To repair the water disposal system or
replace the water depth switch or the pump.
Remove the screws fixing the supporting board.
Remove the screw fixing the pump clamp.
Now, remove the pump and replace.