INSTALLATION AND OPERATION MANUAL
FIGURE 3 – CENTRAL UNIT SWITCH SETTINGS
Dip Switch is located beneath the casing of each unit.
Expansion Module Setup
See Expandion Module information beginning on Page 8.
Pullup Resistors Enabled using Switch #4
ON = DISABLED
OFF = ENABLED
ON
FIGURE 4 – REMOTE UNIT SWITCH SETTINGS
Dip Switch is located beneath the casing of each unit.
Expansion Module Setup
See Expandion Module information beginning on Page 8.
Pullup Resistors Enabled using Switch #4
ON = ENABLED
OFF = DISABLED
ON
FIGURE 5 – DATA I/O SWITCH SETTINGS
Dip Switch is located beneath the casing of each unit. Data selection is made using switches 6, 7 and 8.
}
ON
TECH SUPPORT: 1.888.678.9427
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
Manual Correction:
When using F/2F
card readers, such as the
CASI-RUSCO 941, data may
not be properly transmitted
by default.
The solution to this problem
is to enable the remote unit's
pull up resistors.
This can be achieved by
turning the remote unit's DIP
switch number 5 ON while the
device is in run mode.
Switch
6
7
8
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
INS_FDW1000_EXP100_REV– 04/25/12 PAGE 3
FDW1000(M,S)