Electrolux 36" Ceramic Panduan Petunjuk Instalasi - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Kap Ventilasi Electrolux 36" Ceramic. Electrolux 36" Ceramic 7 halaman. 30” and 36” free-standing range hood
Juga untuk Electrolux 36" Ceramic: Panduan Penggunaan dan Perawatan (26 halaman), Panduan Pemasangan, Penggunaan & Perawatan (22 halaman), Panduan Petunjuk Instalasi (25 halaman), Panduan Petunjuk Instalasi (8 halaman)
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
or Metal Cabinet
24" (61 cm) Min. when
Bottom of Wood or
Metal Cabinet is
Protected by Not Less
Than 1/8" Flame
Retardant Millboard
Covered With Not Less
Than No. 28 MGS Sheet
Steel, 0.015" (0.4 mm)
Stainless Steel, 0.024"
(0.6 mm) Aluminum or
0.020" (0.5 mm)
Copper
2 1/2" (6.4 cm) Min. From Edge
of Cutout to Front Edge of
Countertop
Letters on this figure refer to chart on front page except for J & K.
To eliminate the risk of burns or
CAUTION
fire by reaching over heated surfaces, cabinet
storage space located above the cooktop
should be avoided. If cabinet storage is
provided, risk can be reduced by installing a
range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom
of the cabinets.
A
K
Min. Recommended
Distance Between Rear
Edge of Cutout and
Nearest Combustible
Surface Above
Countertop
F
18"
(45.7 cm)
G
24"
(61 cm)
Approximate Location
of Junction Box
30" Ceramic Glass
36" Ceramic Glass
Figure 2 – COUNTERTOP CUTOUT OPENING
2
Min.
10"
( 25.4 cm)
H
12"
(30.5 cm)
It is not recommended to use
drawer underneath cooktop. Empty
space is needed for installation
purpose.
M O D E L
J
7½" (19.1 cm)
7½" (19.1 cm)
J
Min. From Edge of
Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
K
2" (5.1 cm)
2" (5.1 cm)